Sleep Mode Auto Operation - Panasonic CS-C9BKNG Service Manual

Table of Contents

Advertisement

mode operation.
- Room temperature adjustment.
The following are added to the setting temperature specified as
above.
- The mode judging temperature and standard setting temperature
can be increased by 2°C, by open the circuit of JX1 at indoor
electronic controller.

8.5. Sleep Mode Auto Operation

Cooling or Soft Dry Operation
Purpose is to obtain a comfortable room temperature while sleeping. When you press the
SLEEP Mode, the following movement will start to avoid overcooling. /
- Sleep shift operation starts, when the room temperature reaches
the setting temperature or after 1 hour of operation.
- The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later.
- The airflow volume will automatically change to Lo fan speed.
- Sleep Mode operation time is 8 hours, the operation will be stop
after 8 hours.
- When used together with the Timer, the Timer has priority.