3. Secure the cable onto the control board with the holder (clamper).
4. Cable connection to the power supply (220-240 V, 50 Hz) through
knife switch (Disconnecting means).
- Connect the approved polychlorophrene sheathed power
supply cable (1.5 mm
cord to the terminal board, and connect the other end of the
cable to knife switch (Disconnecting means).

10.3.6. PIPE INSULATION

1. Please carry out insulation at pipe connection portion as
mentioned in Indoor/Outdoor Unit Installation Diagram. Please
wrap the insulated piping end to prevent water from going inside
the piping.
2. If drain hose or connecting piping is in the room (where dew may
form), please increase the insulation by using POLY-E FOAM with
thickness 6 mm or above.
CHECK THE DRAINAGE
- Open front panel and remove air filters. / (Drainage checking can
be carried out without removing the front grille.)
- Pour a glass of water into the drain tray-styrofoam.
- Ensure that water flows out from drain hose of the indoor unit.
), type designation 245 IEC 57 or heavier
2
40