1. There is no swinging while indoor fan motor is stopped during Cooling and Soft Dry operation.
2. In Air Circulation operation, when the intake air temperature reaches set temperature, the airflow
direction is changed from upper limit to lower limit. When the intake air temperature falls to 2°C
than set temperature, the airflow direction is changed from lower limit to upper limit.
Vertical Airflow Direction manual Control
- When the manual Airflow Direction Selection Button is pressed,
the automatic airflow is released and the airflow direction louver
move up and down in the range shown in the diagram.
The louver can be adjusted by pressing the button to the desired
louver position.
- When the remote control is used to stop the operation, the
discharge vent is reset, and stopped at the closing position.
8.11. Delay ON Timer Control
- When the Delayed ON Timer is set by using the remote control, the
unit will start operate slightly before the set time, so that the room
will reach nearly to the set temperature by the desired time.
- For Cooling and Soft Dry mode, the operation will start 15 minutes
before the set time.