Progressive Dynamics PD1618 Installation And Operation Manual page 7

Pure sine wave inverters

Advertisement

The PD1600 Series Inverter in a 50A RV Power System
DC GROUND
SHORE
CONNECTION
GROUND
PD55B006
AC DISTRIBUTION PANEL
TO DC LOADS
GROUND
GENERATOR
TRANSFER SWITCH
50A
MAIN
PD9200
SERIES
CONVERTER
PD52 SERIES
GROUND
MAIN NEUTRAL
TO AC LOADS (HOT)
(SHORE/GENERATOR ONLY)
PD60 SERIES
DC DISTRIBUTION PANEL
12V
Battery Bank
PD1600 SERIES
INVERTER
SUB NEUTRAL
15A
20A
TO AC LOADS (HOT)
(SHORE/GENERATOR/INVERTER)
7
DC-
DC+
AC OUT
AC IN
20A
SUB