Pure sine wave inverters

Advertisement

RV-C Connectivity Specification
PD1600 Series Inverter Compatible RV-C Data Groups
Data Group
Product ID
DM RV
Address Claimed
Inverter AC Output Page 1
Inverter AC Output Page 2
Inverter AC Output Page 3
Inverter AC Output Page 1
Inverter Configuration
Status Page 1
Inverter Configuration
Status Page 2
Inverter Configuration
Status Page 3
Inverter Configuration
Status Page 4
Inverter Status
DC Status
Temperature Status
PD1600 Series Inverter Compatible RV-C Commands
Inverter Command
Inverter Configuration
Command Page 1
Inverter Configuration
Command Page 2
DC Load Command
General Reset
Periodic Send
n/a
When requested the inverter responds with the make and model
"Progressive Dynamics PD1600 Series vX.XX"
4 seconds
Provides information on Service Points in the event of a fault
n/a
The PD1600 Series inverter selects its address dynamically ensuring
that it doesn't claim the same source address as another device
0.5 seconds
Provides information on AC output frequency, voltage, and current
0.5 seconds
Provides information on peak AC voltage, peak AC current, and AC
bypass ampacity
0.5 seconds
Provides information on AC waveform and AC output power
0.5 seconds
Provides information on AC input voltage
On Request
Provides information on the low battery voltage shutdown threshold.
This is configurable (see below)
On Request
Provides information on the high battery voltage shutdown threshold,
and under/over voltage warnings. These are configurable (see below)
On Request
Provides information on the low battery shutdown delay and low bat-
tery restart threshold.
On Request
Provides information on the AC target voltage, maximum output
power, and over-load delay time
0.5 seconds
Provides inverter status: Disabled, Inverter, AC Pass-through
0.5 seconds
Provides information on DC input voltage and DC input current
0.5 seconds
Provides information on the temperature of the power devices
n/a
The inverter accepts command to turn on/off the inverter
n/a
Command to change the low battery shutdown threshold
n/a
Command to change the high battery shutdown threshold and under/
over warnings
n/a
Command that will startup or shutdown all DC loads of a particular
DC load group. Inverter defaults to load group 0.
n/a
Compatible commands in general reset include: reset fault statistics,
reboot inverter, and reset inverter to default configurations