Pin
Wire Color
7
Black
3
8
Gray
3
9
Red
13
White/Green
14
Brown/Green
15
White/Yellow
16
Yellow/Brown
Shield
n/a
10
Violet
11
Gray/Pink
12
Red/Blue
17
White/Gray
All wires are referenced to GND, so any connected serial or I/O device must share a connection to GND.
If using a TCNM-ACBB1 connection box, connect the reader using cable MQDEC-1703SS-DB25 and refer to the Instruction Manual for writing
details.
For Ethernet models, use Cat 5e or superior M12 D-code cables, such as STP-M12D-4xx.
To meet EMC requirements:
Connect the reader chassis to the plant earth ground by means of a flat copper braid shorter than 100 mm
Conect pin "Earth" of the TCNM-ACBB1 connection box to a good earth ground
Simple Configuration
From the factory, all standard 1D and 2D ABR 3000 models are set up to read Data Matrix barcodes. To configure other codes, perform the
simple configuration using the Smart Teach Interface. A simple configuration does not require Barcode Manager software.

Smart Teach Interface

Smart Teach is designed to improve ease of installation and maintenance.
Status information is clearly presented by means of the five colored LEDs. The single push button provides access to the following modes.
Icon
Description
Test Mode includes bar graph visualization to check static reading performance.
Focus (Aim) turns on the laser aiming cross to aim the reader at the target.
Setup self-optimizes and auto-configures image brightness parameters.
Learn automatically detects and recognizes a single code which is presented to it. Successive Learns will substitute the current
code. To configure multiple codes, use Barcode Manager.
Quick access to the following modes is provided using the push button:
1. Press the button. The
2. Hold the button until the specific mode LED is on (Test, Focus/Aim, Setup, or Learn).
3. Release the button to enter the specific mode.
After the button is pressed, the cycle of LED activation is as follows:
Release button to exit
Release button to enter
Test mode
Focus/Aiming
The reader includes a built-in aiming system to aid in reader positioning. Access the aiming system through the Smart Teach Interface.
1. Apply power to the reader.
2
If using the USB interface without Banner accessory cables, EMC compliance requires USB data and power signals to originate from the same source (computer). Maxi-
mum USB cable length from M12 17-pin connector is 2 meters. Incorrect disconnection can result in damage to the USB hub.
3
Referenced to GND; Outputs become opto-isolated and polarity sensitive when connected through the TCNM-ACBB1 connection box. See the Instruction Manual for
connection details.
4
If using RS422, do not leave floating. See the Instruction Manual for connection details.
P/N 207636 Rev. B
Description
2
USB Data+
Output 2
Output 1
Input Signal 2
not connected
2
USB Data -
not connected
Cable shield connected to chassis and 17-pin connector shell
RS232 Main Serial Interface
-
RX
-
TX
Status LED gives visual feedback.
Release button to enter
Focus (Aim) mode
RS422 FD Main Serial Interface
4
RX-
4
RX+
TX-
TX+
Release button to enter
Release button to enter
Setup mode
Learn mode
Release button to exit
(cycle)
3

Advertisement

Table of Contents
loading