  • Page 1 Instruction Manual DM-143-FBGG Copyright © 02/02 Motic Microscopes, European Division.
  • Page 2 15. Power cord for incident illumination 1. Eyepiece 14. Head 2. Diopter adjuster 3. Eyepiece tubes 16. Zoom 4. Prism housing knob 17. Head holder 5. Head holder locking screw 18. Focus knob 6. Objectives 7. Incident illumination 8. Incident light 21.
  • Page 3 Introduction Thank you for your purchase of a Motic stereomicroscope. Motic stereomicroscopes are precision instruments, subjected to meticulous examination to reach you in perfect condition. Their design combines easy management and optimum functioning with minimum maintenance. The information contained in this manual is likely to go beyond what the average user needs to know to use the stereomicroscope, however, it is provided to answer any queries that may arise.
  • Page 4: Operation

    Assembly All the steps described for the assembly of the stereomicroscope must be undertaken with extreme care, and without forcing the placement of the distinct parts and elements of the stereomicroscope. A. Place the base of the microscope (13) upright on a flat, stable and clean surface. B.
  • Page 5 B. Interpupillary adjustment. 1. Looking through the eyepiece (1), move the eyepiece tubes (3) by taking hold of the prism housing (4) and moving out, or inwards. 2. Interpupillary distance is correct when the two fields of view viewed through both eyepieces appear complete and are unified into one.
  • Page 6 Installing the Software Please install the Motic Images software first by referencing the Quick Start Guide provided in PDF format on the CD. Please keep the CD in the drive to load the correct driver for this Digital Microscope when you plug in the USB cable.
  • Page 7 NOTE: Calibration needs to be done at least once and on at least one objective (we recommend the 10X). When the computer screen or the screen resolution is changed, the calibration needs to be done again. Please read the software Quick Start Guide for further information. Maintenance WARNING: FOR YOUR OWN SAFETY SWITCH OFF AND DISCONNECT THE MICROSCOPE FROM ANY ELECTRICAL SOURCE BEFORE ATTEMPTING ANY MAINTENANCE PROCEDURE TO AVOID THE...
  • Page 8: Troubleshooting

    1. Changing the fuse. a. With a flat screwdriver, lightly press on the slot of the fuse holder cover (Fig. 1) and turn 1/4 in the direction of the arrow marked. b. Release pressure and completely remove the loosened cover. c.
  • Page 9 Bulbs and fuses are not under warrantee. The warrantee service is provided by MOTIC, or its authorised distributors. Defective products will be repaired free of charge when returned to MOTIC, or one of its distributors. Transport costs will be covered by the purchaser.