Omron Vision Sensor FH Series Connection Manual page 58

Robot yaskawa electric corporation edition
Hide thumbs Also See for Vision Sensor FH Series:
Table of Contents

Advertisement

FHRUNRECVVAL
7.5.7.
 Function
Receive numerical data from the Vision Sensor
 Syntax
SET S089 "FHRUNRECVVAL"
 Parameter
Argument
I097
I098
R090 – R099
I099
 Remarks
This function stores the numerical data sent from the Vision Sensor into the register
specified by the variables "R090" to "R099".
This function outputs up to 10 values.
If there are more than 11 numbers, this function outputs only the first 10.
If the length of the segmented string is longer than 12 bytes, this function returns an
error of abnormal parameter length.
Returns an error if the number of numeric data is zero.
The following is an example of the output when a string is included.
<Conversion example>
The string before conversion
abc
123abc
abc123
1.00E+03
 Return Value
Err. No.
Error Message
0
-
-1300
ERROR:fhrecvstring():RETRY:-1300
Input/Output Data type
Input
Integer
Input
Integer
Output
Real
Output
Integer
Description
Number of receive retries (0 to 99)
Receive timeout time (0 to 99sec)
Results of the analysis of the received
numerical sequence (Element count:
10)
error number
Store the result of the execution of
this function.
The result of the analysis after conversion
0
123
0
1000
56
Description
normal termination
Out of the range of

Advertisement

Table of Contents
loading