Page 1
M O N I T O R I N G & C O N T R O L S O L U T I O N S EtherStax Series ® Ethernet I/O Modules Modbus TCP/IP Modbus UDP/IP ® Peer-to-Peer Rugged, Stackable Analog and Discrete High-Density I/O 8400-453g...
Page 2
Most products can be shipped within 24 hours of receiving your order. 50 Years of I/O Experience Special Services Acromag has more than 50 years of measurement and control experience. We are happy to accommodate your Since 1957, we have delivered nearly a...
Page 3
ES2171 16 current outputs....28 ES2172 16 voltage outputs....30 Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■...
Page 4
Recommended Connections Optional Connections and do not require a (switched Ethernet) (two cascaded nodes) cross-over cable when making copper network connections Connect to Port 1 Connect one unit Acromag per switch port Acromag R.M. PWR1 ETHERNET 10/100M STATUS ETHERNET STATUS PWR2...
Page 5
Earth ground terminal Fault relay One on each side Local 5A Form A relay Network and I/O Configuration Screens Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 5 –...
Page 6
Peer-to-Peer Bi-Directional Communication Redundant Ring Connections Chan Chan Chan Chan Chan Chan Acromag 1-16 17-32 33-48 49-65 66-81 82-96 PW R R.M. Switch PW R1 PW R2...
Page 7
Hub/repeater mode: fixed at 100Mbps and auto-nego- Electromagnetic Compatibility (EMC) tiation does not apply. Meets EN50082-1. Electrostatic Discharge (ESD) Immunity Meets EN61000-4-2. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 7 –...
Page 8
Remote control switching stations No software. No programming. six current, voltage, thermocouple, or RTD ■ Acromag Ethernet I/O modules have a built-in sensor signals. This data is then transmitted to a Environmental control systems ■ web page making it simple to configure using...
Page 9
Ethernet I/O: EtherStax Series ® Acromag i2o Technology for Peer-to-Peer Communication ® ES2000 Series Units with i2o Analog Input Modules ◆ ES2153 Ethernet 16 analog current inputs, Media 16 analog voltage or 8B inputs Analog Output Modules ◆ ES2171 16 current outputs...
Page 10
I/O is protected from excessive levels to reduce Event-driven updates transmit data in less than Modbus TCP/IP or UDP/IP protocol downtime. 5mS between peers with i2o. Acromag i2o® peer-to-peer technology 10 Modbus TCP/IP sockets/sessions: Power Requirement ■ Multiple masters can talk to an EtherStax unit 18 to 36V DC (redundancy-ready) at the same time.
Page 12
10/100Base-T(X) and 100Base-FX Automatic change of state detection: Modbus TCP/IP or UDP/IP protocol ■ Inputs detect quick momentary changes of Acromag i2o® peer-to-peer technology state that occur between polling. Power Requirement Logic inversion (i2o only): 18 to 36V DC (redundancy-ready) ■...
Page 13
Hazardous Locations: Class I; Div 2; A, B, C, D. Open board units: UL Recognized. Shock and Vibration Immunity (in enclosure) Mechanical Shock: 50g (3ms), 30g (11ms). Random Vibration: 5g, (5-500Hz). Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■...
Page 14
Peer-to-peer i2o communication with ■ percent-of-span and timed updates Interface to 8B signal conditioning modules. Select from more than 100 8B input modules. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■...
Page 15
400 ohms @ 12V. 540 ohms @ 15V. Output Resolution and Accuracy Resolution: 13-bit maximum, 0.0122%. Accuracy: Better than 0.1% of range. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■...
Page 16
Peer-to-peer i2o communication with ■ percent-of-span and timed updates Interface to 8B signal conditioning modules. Select from more than 100 8B input modules. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■...
Page 17
Continuous: 250V AC, 354V DC (150V AC ch-ch). Resolution (±10V): 16-bit maximum, 0.00166%. Resolution (±5V): 15-bit maximum, 0.00305%. Accuracy: Better than 0.05% of range. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■...
Page 18
Peer-to-peer i2o communication with ■ percent-of-span and timed updates Interface to 8B signal conditioning modules. Select from more than 100 8B input modules. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■...
Page 19
2A @ 24V DC/250V AC, Hazardous locations. Random Vibration: 5g, (5-500Hz). Maximum Switching Voltage and Power 250V AC / 750VA, 125V DC / 90W. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■...
Page 20
Built-in precision voltage source for ■ automatic calibration On-demand self-test with built-in ■ calibration sources Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 20 –...
Page 21
3A @ 24V DC/250V AC, 100,000 cycles general. 2A @ 24V DC/250V AC, Hazardous locations. Maximum Switching Voltage and Power 250V AC / 750VA, 125V DC / 90W. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■...
Page 22
On-demand self-test with built-in Interface to 8B signal conditioning modules. ■ calibration sources Select from more than 100 8B input modules. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 22 –...
Page 23
Configurable IP addresses. Ethernet Modbus TCP/IP Sockets/Sessions 1-10 socket/sessions programmable via web page. Ethernet Redundancy Compatible with STP, RSTP, proprietary schemes. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 23 –...
Page 24
Scaling registers on all channels ■ small footprint. Open circuit board versions are also available. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■...
Page 25
3A @ 24V DC/250V AC, 100,000 cycles general. 2A @ 24V DC/250V AC, Hazardous locations. Maximum Switching Voltage and Power 250V AC / 750VA, 125V DC / 90W. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■...
Page 26
Scaling registers on all channels ■ small footprint. Open circuit board versions are also available. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■...
Page 27
3A @ 24V DC/250V AC, 100,000 cycles general. 2A @ 24V DC/250V AC, Hazardous locations. Maximum Switching Voltage and Power 250V AC / 750VA, 125V DC / 90W. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■...
Page 28
Peer-to-Peer Messaging stack vertically to maintain a very small footprint. With Acromag’s i2o technology, you can map inputs from ES215x units to output channels on an ES2171 module. Select updates based on time or on a percent of range change (100mS or Open circuit board versions are also available.
Page 29
Random Vibration: 5g, (5-500Hz). Ethernet Modbus TCP/IP Sockets/Sessions 1-10 socket/sessions user-configurable. Ethernet Redundancy Compatible with STP, RSTP, or any ring scheme. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 29 –...
Page 30
Peer-to-Peer Messaging stack vertically to maintain a very small footprint. With Acromag’s i2o technology, you can map inputs from ES215x units to output channels on an ES2172 module. Select updates based on time or on a percent of range change (100mS or Interface to isolated 8B analog output modules.
Page 31
StaticIP, DHCP. Ethernet Modbus TCP/IP Sockets/Sessions 1-10 socket/sessions user-configurable. Ethernet Redundancy Compatible with STP, RSTP, or any ring scheme. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 31 –...
Page 32
Ordering Information This new line of high-density isolated signal Systems requiring high channel-to-channel ■ NOTE: Please refer to Acromag Bulletin #8400-479 or conditioners provides 17 family groups with a isolation, noise rejection, surge suppression, visit www.acromag.com for full ordering information.
Page 33
900EN-S005 is used EIS408FX-M as a simple switch with Acromag I/O modules. Managed or unmanaged operation Ethernet switch with redundancy, 6 Cu / 2 Fiber-optic, For advanced users, this switch offers numer- multi-mode fiber (up to 2 km).
Page 34
Side-by-side 19-inch rack mounting with ESA- plies standoffs to stack two units. DIN rail with ESA-DIN-HMK kit plate. DIN-HMK kit on a DIN rail. Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■...
Page 35
Wiring Accessories For your convenience, Acromag offers several PS5R-S Slim Line models give you all the power Acromag offers a variety of data cables and mounting accessories to simplify your system of a traditional power supply in only half the signal adapters to complete your application.
Page 36
Acromag Ethernet I/O with your code with provided function calls to configure, application program. read, and write to Acromag I/O modules. Ideal for Windows, Linux, VxWorks, and QNX OS. OPC DA Server This low-cost server is exclusively for use with Key Features &...
Page 37
Ethernet I/O: EtherStax Series ® Notes Tel: 248-295-0880 Fax: 248-624-9234 sales@acromag.com www.acromag.com 30765 S Wixom Rd, Wixom, MI 48393 USA ■ ■ ■ ■ – 37 –...