Download Print this page

Friedrich VERT-I-PAK Series Product Profile

Single package vertical air conditioners and heat pumps
Hide thumbs Also See for VERT-I-PAK Series:

Advertisement

Quick Links

VERT-I-PAK * Product P rofile
SinglePackage Vertical A irConditioners andHeatPumps
A SERIES
9,000/ 12,000/ 18,000/ 24,000Btu/h
New smaller closet
dimensions.
Compact and lightweight-
weighs as little as 125 Ibs.
Unique free-floating chassis.
10" crimped and beaded duct-
collar ready to attach flex-duct.
i
Easy to connect right, left or
rear drain connection.
Optional seacoast protection
for harsh coastal environments.
Easy to install front, left or right
hand into closet.
V ¸
R SERIES
18,000 / 24,000 / 30,000 / 36,000
42,000 / 49,000 / 60,000 Btu/h
Indoor return air and outdoor
air can be ducted to allow
installation in an interior
closet.
Comes shipped with a
preformed discharge
flange.
Cooling mode freeze
protection.
Heat pump operation
down to 0°F.
Easy service access
from front of unit.
StandardFeatures
Completely self-contained unit.
Available in heat pump or electric heat.
No outside condensing unit, eliminatingthe
need for external electrical wiring, landscaping
and vandalism barriers.
Easy installation;unit is wired and charged at
the factory.
No refrigerant lines running from floor to floor.
All units are shipped with return air filter
installed.
An individual packaged unit can be used to heat
or cool multiple rooms.
Cabinets are fully insulated for improved sound
characteristics and unit performance.
Safety power disconnect.
Remotethermostat-ready 24-volt transformer.
Complete line of accessories.
Manufactured in the U.S.A.
VPAC-BW-04 (4-04)

Advertisement

loading

Summary of Contents for Friedrich VERT-I-PAK Series

  • Page 1 VERT-I-PAK * Product P rofile SinglePackage Vertical A irConditioners andHeatPumps A SERIES R SERIES 9,000/ 12,000/ 18,000/ 24,000Btu/h 18,000 / 24,000 / 30,000 / 36,000 42,000 / 49,000 / 60,000 Btu/h New smaller closet Indoor return air and outdoor dimensions. air can be ducted to allow Compact and lightweight- installation in an interior...
  • Page 2 r. HAS A SERIES VEA12K VEA24K VHA12K VHA24K COOLING DATA 11800/11500 24000 11800/11500 23500 Cooling BTU/h iiiiiiiiiiiiiiiiiiiiiiiiiiiiii!_i_iiiiii:ii ¸,',_',I,',,',_',I,',,',_',I,',,',_',I,', i i iiiiiiiiiiiiiiiiiiiiiiiiiiiiii!_!_!!!_!'!,i,ij_ii!iiiii!_i_iiill ¸II:!I_ 1093 2526 1124 2474 CoolingPower(W) 10.8 10.5 SensibleHeatRatio 0.72 0.70 0.72 0.70 HEAT PUMP DATA 10600/10400 22500 HeatingBtu/h Cop@ 47°F 2200 HeatingPower(W)
  • Page 3 r. HASS _® A SERIES OUTDOORDRYBULB TEMP.(DEGREESF AT 40% R.H.) INDOORWET BULB TEMP.(DEGREESF AT 80 F D.B.) BTU/h 11172 10745 9947 10640 10032 9253 10222 8408 9576 8503 7496 8522 7334 6479 Watts 1038 1038 1042 VEA09 Amps 0.51 0.69 0.93 0.52 0.7I...
  • Page 4 B SERIES VEB18K VEB30K VEB42K VEBBOK COOLING DATA 17000 30000 42000 58000 CoolingBtu/h !!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_!_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii i_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii9_!8!!_iiiiiiiiiiiiiiiiiiiiiiiiiiii SEER 10.0 10.0 !!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_!!_i_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii _iiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_!_i!i_i_i_iiiiiiiii SensibleHeat Ratio 0.78 0.70 0.72 0.72 ELECTRICAL DATA 230/208 230/208 230/208 230/208 Voltage(1 Phase,60 Hz) ..iiiiiiiiiiiiiiiiiiiiii!_i!!i_iiiiiiiiiiiiiiiiiiiiiiiiiiii 253-198 253-I98 253-198 253-198 Volt Range !!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!i_ii_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii...
  • Page 5 r. HASS S PE r. ATI D N S B SERIES OUTDOOR DRYBULB TEMP. I DEGREE8F AT40% R,H. 1 INDOOR WETBULBTEMP.DEGREES F AT80 F D.B. BTU/h 20420 19640 18160 18860 18140 16780 17680 15730 16390 15760 14580 15700 15100 13960 14980 14410 13330 VEBi8 / Watts 1549...
  • Page 6 ELECTRICAL DATA B SERIES MultipleCircuits Single Circuit HACR / Groung Factory HACR / Breaker Wire Size Wire Size Circuit Voltage Max Breaker Size Wire Size (field) Groung Wh'e Size (field', Size (field) (field) Breakers Voltage / Hz / Ph Range Ckt 1 Ckt 2 Ckt 1...
  • Page 7 P.O. # Date: Location: Project: Engineer: Architect: Submitted For Reference: For Approval: ITEM PLAN DESIGNATION QUANTITY FRIEDRICH MODEL COOLING BTU/H VOLTAGE A-SERIES ACCESSORIES [Wall Plenum and Outdoor Louver are rec uired.] VPAWP1-8 Adjustable Wall Plenum (5-1/2"-8") VPRG4 Return Air Grille/Access...
  • Page 8 • Chassis is to be installed against an exterior wall. Wall cutout dimensions will be 24_/8 " w x 307/8" • The use ofa Friedrich wall plenum is required for installation. Plenum opening is 314" above the floor. (VPAWP1-8 t VPAWP1-14).
  • Page 9 APPLIRATIDN DIMENSIDNS A SERIES • New design utilizes drain pan (VPDP1) that can be installed prior to chassis for simplified installation and removal. • Utilizes same wall plenum as otherA Series units to give consistent exterior appearance. VEAtVHA24 plenum must be installed 1 I/2" 47r/4 '' off of chassis platform.
  • Page 10 ACCESSORIES A SERIES DESCRIPTION PHOTO MODEL WALL PLENUM Two-partsleeve that telescopes in and out from 51/2 ' ' to 8" in depth. The wall plenumsits insidethe exterior wall VPAWP1-8 penetration. DIMENSIONS:303/8 " high x 24%"wide. CUTOUT DIMENSIONS:307/_ ' high x 24s/_ ' wide. VPAWP1-14 Same as VPAWP1-8, but telescopes8"...
  • Page 11 ACCESSORIES B SERIES MODEL DESCRIPTION PHOTO Telescoping wall plenumsadjustto exactwall depth.Modelswith -8 suffixesadjust41/2 ' ' - 8" deep;-14 models adjust8" - 14", WALLPLENUM-Usedwhen chassisis positionedagainstan exteriorwall for outdoor air infiltration. Recommended for usewith 18,000and 24,000Btu/h units. VPBWP3-8 DIMENSIONS: 1 81/4 ' ' highx 28_/2 ' wide. VPBWP3-14 CUTOUTDIMENSIONS: 18_/2 ' ' high x 281/2 ' ' wide.
  • Page 12 36 = 36,000 VOLTAGE K = 208/230V-1Ph-60Hz Multiple so utiOnSo Onetrusted name. Friedrich Air Conditioning Co. PostOfficeBox1540 SanAntonio, T X 78295-1540 4200N. Pan Am Expressway SanAntonio, T X 78218-5212 (210)357-4400 fax (210)357-4480 www.friedrich.com Dueto continuingresearch in new energy-savingtechnology,specifications are subjectto changewithout notice.