Time
Activity
2x daily
Check
Check
weekly or if the
Clean the filter
indicator lamp
"fault" glows red
Clean the filter
Quarterly
Check
Clean the filter
*) "Slag from oil separation unit" - in Germa-
ny it comes under waste category no.
190813
16
Maintenance schedule
Assembly affected
Dosing container for liquid split-
ting agent and for sterilisation
agent (only while reusing the
purified waste water).
Dosing unit for splitting powder Check filling level and refill if required up to maxi-
Filter unit
Filling level probes in the filter
unit of the reaction tank (behind
the switching cabinet without
diagram) and storage tank for
processed water.
All water-carrying hose pipes.
Complete plant from the inside.
EN
Performance
Check filling level and top up if required; close the
filled container properly.
mum 2/3; avoid excess filling.
Check dirt level; replace filter, if required; further:
Open the front door of the filter unit.
Pull out the dirty recycling filter or filter for split-
ting powder and replace with a new filter.
Insert the overflow hose into the bag on the inner
side of the filter.
Drain off the dirt-loaded filter and dispose off the
content according to the statutory regulations! *)
Clean the filling level probes with moist cloth to clean
off the dirt sticking to it.
Are the hoses bent, blocked or damaged? If yes, rec-
tify the damage or replace the hose.
Turn the main switch to position "0"
Pull out the mains plug.
Empty all containers; guide the drained water
into the slag collector or dispose off externally. *)
Spray off the dirt sticking to the inner walls using
a water hose (max. 0.6 MPa) and let the water
drain off.
Do not use high-pressure cleaner! Electronic
components can get damaged.
5
-
of whom
Operator
Operator
Operator
Operator
Operator
Operator