HDS Super, HDS 655, HDS 695 S, HDS 895 S, HDS 1195
Burner not ignited
Fuel tank empty
– Fill up
Lack of water
– Check water connection, check supply lines,
clean low water protection.
Fuel filter dirty
– Replace fuel filter.
Incorrect direction of rotation. If direction of
rotation is correct, powerful jet of air will be felt
at exhaust-gas opening of burner.
– Check direction of rotation. If
necessary change the poles at the unit plug.
See Figure 16.
No ignition spark
– Have unit checked by After-Sales Service if
no ignition spark is visible through inspection
glass during operation.
Set temperature not attained when working
with hot water
Excessive operating pressure/flow rate
– Reduce operating pressure/flow rate by way
of regulator (Figure 9)
Soot deposits on heating coil
– Have After-Sales Service remove soot
deposits from unit
If the problem cannot be resolved the unit
must be checked by after sales service.

WARRANTY

The warranty terms and conditions issued by
our responsible sales company apply in every
country. Within the warranty period, any faults in
the unit will be rectified free of charge provided
that the problem was caused by a material
defect or manufacturing error.
The warranty only applies if the dealer fills in,
stamps and signs the enclosed reply card when
the unit is sold and the purchaser then returns it
to the appropriate local distributor.
In the event of a warranty claim, please contact
your dealer or the nearest authorised After-
Sales Service office and produce both
accessories and proof of purchase.

GENERAL INSTRUCTIONS

Safety features
* Overflow valve with two pressure switches
When reducing water volume at pump head or
with the servopress control, the overflow valve
will open and part of the water will flow back to
the pump suction side.
If the handgun is closed thus causing all the
water to return to the pump suction end, the
pressure switch at the overflow valve shuts off
the pump.
Reopening the handgun causes the pressure
switch at the cylinder head to switch the pump
back on again.
The overflow valve is set at the factory and
lead-sealed. Adjustment can only be made by
After-Sales Service.
* Safety valve
The safety valve opens if the overflow valve or
pressure switch is defective. The safety valve is
set at the factory and sealed. Adjustment can
only be made by After-Sales Service.
* Low water protection
The low water protection stops the burner being
switched on in the event of a lack of water. A
strainer stops the protection feature becoming
dirty and requires regular cleaning.
* Motor protection switch
The motor protection switch interrupts the circuit
should overloading occur.
Guidelines for liquid spraying equipment
* The accident prevention directive (BGV D 15)
Work with Jets of Liquids is applicable. In
accordance with these guidelines, high-
pressure spraying equipment must be
checked at least every 12 months by an
expert and the results of the inspection
recorded in writing.
Order governing boilers
* The testing pressure and the design of the
unit comply with the steam boiler directive!.
The water content of the heating coil is less
than 10 litres. The boiler section of the unit is
thus not subject to installation regulations.
Local building regulations are to be heeded.
Switching on procedures
* Switching on procedures generate brief
voltage drops. Impairments of other
appliances can occur in cases of
unfavourable mains conditions. No problems
are to be expected with a mains impedance of
less than 0,15 ohm.