Technical Specifications; Transport; Storing The Device; Maintenance And Care - Kärcher WRP 3000 Comfort Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
Monitoring and regulating equipment
Float switch in the recycled water tank
Floater switch in the pump basin
If the pump basin was completely empty
(dry run), the pump basin will first have to
be completely filled.
Immersion pump
Motor output
Voltage
Power consumption
Flow rate at approx. 0.25 MPa (2.5 bar)
Pressure
Entire unit
Filter capacity
Voltage
Frequency
Width
Depth
Height
Weight

Transport

Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
In der Anlage enthaltenes Restwasser
muss vor dem Transport entfernt werden.
When transporting in vehicles, secure the
appliance according to the guidelines from
slipping and tipping over.

Storing the device

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
In der Anlage enthaltenes Restwasser
muss vor der Lagerung entfernt werden.
Store the appliance in a frost free area.
S7 top
Recycled water tank full. Filling process is stopped.
S7 bottom
Recycled water tank is filled.
S9 top
Switching off the fresh water supply. Indicator lamp "Fresh water supply active" goes
off. Illuminated lamp "Fresh water supply was active" lights up red.
S9 bottom
Switching on the fresh water supply. Indicator lamp "Fresh water supply active" and
"Fresh water supply was active" lights up red.
S11 top
Dry run protection for wash pump not active, no error message.
S11 bottom
Dry run protection for wash pump active, error message on the washing system.
S5 top
Pump basin overfilled. Starting the disposal via the recycling water tank into the channel
S5 bottom
Pump basin is not overfilled, normal system operation.
S4.1 top
Pump basin is not sufficiently filled, normal system operation.
S4.1 bottom
no function
S4.2 top
no function
S4.2 bottom
Pump basin empty, dry run protection of immersion pump active, no filtration, no back-
wash possible. System runs on fresh water.
Then, the swimmer switch S4.1 will release
the submersion pump and normal opera-
tion is warranted once more.

Technical specifications

Maintenance and care

Maintenance instructions
The bases of a safe operating of the equip-
ment is thr regularly maintenance accord-
ing to the following maintenance plan.
Use only original parts of the manufacturer
or part suggessted by him, such as
replacement and wear parts
Accessory parts
Fuel
Detergent
Danger
Risk of accident while working on the unit.
During all tasks
 Deenergize the system: Pull the mains
plug and secure the system against be-
ing switched back on.
 Shut off water supply.
6
-
EN
WRP 3000 Comfort
W
V
A
m
/h
3
MPa (bar)
m
/h
3
V
Hz
mm
mm
mm
kg
Who may perform maintenance?
Operator
Work designated with the sign "Opera-
tor" may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the
washing system.
Customer Service
Only KÄRCHER service engineers are
allowed to carry out work with the note
"Customer Service".
Maintenance contract
In order to ensure a reliable operation of the
plant, we recommend that you conclude a
maintenance contract with us. Please refer
to you local KÄRCHER service depart-
ment.
1000
230/1~
4,4
asi 3
max. 0,25 (2,5)
max. 3
230/1~
50
630
480
1400
55
17

Advertisement

Table of Contents
loading

Table of Contents