Electrical connection
Voltage
Current type
Frequency
Connected load
Inlet lock
FI safety switch
Water connection
Appliance connection (hose)
Max. feed temperature
input amount
Water pressure
Performance data
pressure with nozzle 5004
Flow rate
Reduced flow rate
warm water temerature in the SB operation is limited to
Detergent suction (at 20 °C)
reaction power pressure of the hand blowing gun including the nozzle 5004
Dimensions
Width
Depth
Height
Weight with accessories and packaging
Miscellaneous
Oil quantity of HP pump
kind of oil (ordering number: 6.288-218.0)
base exchanger (optional)
Capacity
usage of salt for each regeneration
salt tank capacity
Values determined as per EN 60335-2-79
Hand-arm vibration value
Hand spray gun
Spray lance
Uncertainty K
Sound pressure level L
pA
Uncertainty K
pA
Sound power level L
+ Uncertainty K
WA
Technical specifications
WA
EN
V
Hz
kW (max.)
A (slow)
delta I in A
Inch
°C
I/min
MPa (bar)
MPa (bar)
l/h (l/min)
l/h (l/min)
°C
l/h (l/min)
N
mm
mm
mm
kg
l
°dH/m
kg
l
m/s
2
m/s
2
m/s
2
dB(A)
dB(A)
dB(A)
8
-
0,3...0,6 (3...6)
ca. 500 (8,3)
ca. 250 (4,2)
0,9...1,8 (15...30)
3
220
1~
50
max. 6,0
35
0,03
3/4
30
10
10 (100)
max. 45
max. 20
1040
725
1375
245
0,75
0-W40
65
ca. 3,75
35
<2,5
<2,5
1
65
2
71
29