Time
Activity
daily
opinion
weekly
Clean the
filter
opinion
monthly
opinion
Clean the
filter
half-yearly
opinion
empty,
clean
Check
throughflow
quantity
annual
.
Float sensor level
S7 top
S7 bottom
S9 top
S9 bottom
S11 top
S11 bottom
Litering out the filter
 Switch off the system.
 Drain half the recycled water tank
through the drain valve (up to the con-
nection of the recirculation valve).
 Close the drain valve.
 Measure the distance between the wa-
ter surface and the rim of the cover in
the recycled water tank (use a metre-
stick and a flashlight).
 Switch on the system and let it run for exact-
ly 5 minutes. Switchoff the system.
 Measure the water level again.
18
Maintenance schedule
Assembly af-
Performance
fected
Indicator lamps
When this indicator lamp lights up, solve the problems according to instruc-
"Error"
tions in the "Troubleshooting" section
Indicator lamp
Press the illuminated key "Acknowledge message", find the cause for the
"Fresh water
fresh water use and alleviate it.
supply was ac-
tive"
Drain at wash-
Clean the dirt collection basket in the floor.
ing place
Recycling water Check recycled water for odour and turbidity. See the "Troubleshooting"
section for measures against poor quality of recycled water.
Detergent con-
Reduce detergent dose at the washing unit if there is too much foam for-
centration in re-
mation.
cycled water
Filament filter
Check filtering capacity. As long as the washing unit draws waterwater, the wa-
ter level in the recycled water tank must not fall below the starting level S9.
Trigger the manual backwash or clean or change filter module if capacity is
too low.
Swimmer
Check settings and status of the float sensors; inform Customer Service, if
switch
required.
Sludge collec-
After sludge has been collected, there should be no sludge in any of the ba-
tion, pump basin
sins. The sludge in the sludge collector should be maximum 1 m in height.
Check sludge level; pump out and dispose of the sludge, if required. Clean
the basin.
Conductivity
Remove, clean and install the conductivity sensor.
sensor
Backwashing
Does enough water flow from the pipe to the sludge trap during backwash-
ing (1 - 1,5 m
Recycled water
Empty, clean, rinse and refill.
tank
Ventilation
If the ventilation is running, bubbles are visible in the pump basin.
Immersion
The flow rate is correct if the water level in the processed water tank does
pump
not fall below level S9 at the bottom when the washing unit is being oper-
ated.
Filter inlay
Replace filter inlay of the filament filter.
 Determine the filling capacity of the
tank.
With 1 tank: (height difference in cm) x
72 = filling capacity in litres per hour
With 2 tanks: (height difference in cm) x
144 = filling capacity in litres per hour
 Add 500 l/h to the determined filling capaci-
ty (loss by recirculation during filling).
Example:
The system has 1 recycled water tank.
Distance to the rim of the cover before
the system is switched on: 81 cm
Distance to the rim of the cover after 5
minutes of system operation: 46 cm
/h = 17 - 25 l/min)?
3
Filling quantity of recycled water
1 tank
960 l
810 l
550 l
410 l
450 l
210 l
7
-
EN
2 tanks
1 920 l
1 620 l
1 100 l
820 l
900 l
420 l
 Height difference: 81 cm-46 cm = 35 cm
 Filling capacity: 35 cm x 72 = 2520 l/h
 Add 500 l/h
Filter capacity of the WRP 3000: 3020 l/h
The system is properly adjusted.

Troubleshooting

Danger
Risk of accident while working on the unit.
During all tasks
 First switch-on in voltage-less state,
press the emergency stop switch and
secure it against being switched on
again (remove mains plug).
 Shut off water supply.
By whom
Operator
Operator,
Customer
Service
Operator
Operator
Operator
Operator
Customer
Service
Operator
Operator
Operator,
Customer
Service
Customer
Service
Operator
Customer
Service
Customer
Service
Operator,
Customer
Service

Advertisement

Table of Contents
loading

Table of Contents