Technical Specifications; Declaration Of Conformity - STEINEL L 265 S Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
Serie L 265_24spr
17.07.2008
Adjusting the detection zone
The detection zone can be limited to suit requirements. The
shrouds supplied with the light can be used to mask out as
many lens segments as you wish.This prevents the light from
being activated unintentionally, e.g. by cars, passers-by etc.
Manual override function
If a mains switch is installed in the mains supply lead, the light
is capable of the following functions in addition to the simple
"ON"/"OFF" function:
Sensor mode
1) Switch light "ON" (when light is "OFF"):
Turn switch "OFF" and "ON" once.
Light stays "OFF" for the period selected.
2) Switch light "OFF" (when light is "ON"):
Turn switch "OFF" and "ON" once.
The light goes out or switches to sensor mode.

Technical specifications

Output:
Voltage:
Angle of coverage:
Sensor reach:
Time setting:
Twilight setting:
Programme setting:
Manual override:
Protection class:
Protection class:
Operation/Maintenance
The SensorLight is suitable for switching light "OFF" automati-
cally. Weather conditions may affect the way the SensorLight
functions. Strong gusts of wind, snow, rain or hail may cause
the light to come "ON" when it is not wanted because the
sensor is unable to distinguish sudden changes of temperature

Declaration of conformity

This product complies with Low Voltage Directive 06/95/EC,
EMC Directive 04/108/EC and RoHS Directive 02/95/EC.
11:01 Uhr
Seite 12
and allows you to target danger spots. The shrouds and
shroud foils can be divided along the grooves. They can then
simply be pushed or stuck onto the lens.
Manual override
1) Activate manual override:
Switch 2 x "OFF" and "ON". The light will stay on for 4 hours
(red LED lights up behind the lens).
Then it returns automatically to sensor mode (red LED off).
2) Deactivate manual override:
Turn switch "OFF" and "ON" once. The light goes out or
switches to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
LED effect light and LED Power light, approx. 1W
Low-energy bulb with max. diameter of 48 mm
Tip: Choose cool white (6000 K) and the LED will harmonise very well with the main light.
230 – 240 V, 50/60 Hz
360° with 90° angle of aperture and sneak-by guard
8 m max. all round
5 sec. – 15 min.
2 – 2000 lux
4 programmes geared to practical needs (see above)
selectable (4 hours)
provided switch in mains power supply lead
IP 44
II
from sources of heat. The detector lens may be cleaned with
a damp cloth if it gets dirty (do not use cleaning agents). The
mini-sensor unit
corona
- 11 -
can be removed for cleaning the LED
.

Advertisement

Table of Contents
loading

Table of Contents