Disconnect from electricity and gas before servicing. Check ap pli ance is safe when you have finished.
Lift up the ends of the plastic clips (one each
side) to release the catches holding the drawer
to the side runners and at the same time pull the
drawer forward and away from the side runners.
For safety's sake push the drawer runners back
out of the way.
The regulator is now accessible. Unscrew the
brass top of the regulator.
In the base of the brass top is a plastic snap in
converter device.
Natural gas
To convert the regulator snap the device out of
the top and refi t the other way up. The snap in
converter device is marked to show which gas it
is set for. Make sure the device is secure in the
top cap and refi t the cap to the regulator.

Stick on label

Stick the appropriate label on to the data badge
to indicate the gas the appliance is now set for.
SERVICING - WARNING

Pressure Testing

Refit the storage drawer
Check the appliance is gas sound.
Check operation of all the burners.
Propane gas
47
Connect the appliance to the gas supply. Check
the appliance is gas sound.
The gas pressure can be measured at one
of the central cooktop burner orifi ces. Lift off
a burner head. Fit the pressure gauge to the
orifi ce. Turn on the cooktop burner and turn on
and light one of the other burners.
Reassemble burner top, making sure it is
reassembled in the correct way on the burner
body.
To refi t the drawer pull out the side runners.
Rest the drawer back on the side runners and,
keeping it level, push it right back. The clips
should click into position holding the drawer to
the side runners. Replace the drawer by locating
on side runners and push in.

Hide quick links: