Fig.14
MECHANICAL SEAL SPECIFICATIONS (IN ACCORDANCE WITH EN 12756) VERSION K
Standard version
Position
A
B
Model
Stationary
Rotating
part
part
Graphite
Silicon Carbide
E1
B
Q
A
B
C
30 VR 15
VR
F G
Fig.15
Power motor
P2
2 pole - 2900 rpm
[kW]
Size motor IEC
0,37
71
0,55
71
0,75
80
1,1
80
1,5
90
2,2
90
3
100
4
112
5,5
132
7,5
132
11
160
15
160
18,5
160
22
180
30
200
37
200
45
225
* Sound pressure level measured in free field at 1 mt distance from the electic pump.
46
Original instructions
C
D
Temperature
Other
Elastomers
components
AISI 316
EPDM
-30 °C
G
E
+120 °C
TIPO U
D
015
E1
E
50Hz
4 pole - 1450 rpm
LpA*
Size motor IEC
<70
71
<70
71
<70
80
<70
90
<70
90
<70
100
<70
100
<70
112
<70
132
72
132
74
-
75
-
75
-
75
-
75
-
75
-
78
-
Available on request
Position
A
B
Model
Stationary
Rotating
part
part
Silicon Carbide
Silicon Carbide
E2
Q
Q
Silicon Carbide
Silicon Carbide
V3
Q
Q
Carbon
Silicon Carbide
V4
B
Q
Tungsten Carbide
E5
U
Tungsten Carbide
V6
U
A
B
C
30 VR 15
VR
F G
dB +/- 3
2 pole - 3600 rpm
LpA*
Size motor IEC
<70
-
<70
71
<70
80
<70
80
<70
90
<70
90
<70
100
<70
112
<70
132
<70
132
-
160
-
160
-
160
-
180
-
200
-
200
-
225
Temperature
C
D
Other
Elastomers
components
AISI 316
EPDM
-10°C +120°C
G
E
AISI 316
FKM
-10°C +120°C
G
V
AISI 316
FKM
-10°C +120°C
G
V
AISI 316
EPM
-10°C +120°C
G
E
AISI 316
FKM
-10°C +120°C
G
V
TIPO B
D
015
E
E1
60Hz
4 pole - 1800 rpm
LpA*
Size motor IEC
-
71
<70
80
<70
80
<70
90
<70
90
70
100
70
100
72
112
73
132
74
132
78
160
78
160
80
-
80
-
79
-
78
-
80
-
[°C]
LpA*
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
<70
-
-
-
-
-

Advertisement