Transport; Storage; Care And Maintenance; Troubleshooting - Kärcher NT 40/1 Tact Manual

Hide thumbs Also See for NT 40/1 Tact:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
 Activate the switch. Indicator lamp in
the switch goes off.
– To switch on automatic filter cleaning:
 Press the switch again. Indicator lamp
in the switch glows green.
Turn off the appliance
 Switch off the appliance at the main
switch.
 Pull out the mains plug.
After each operation
 Empty the container.
 Vacuum and wipe the appliance inside
and outside with a damp cloth.
Installing/removing the pushing
Illustration
Storing the Appliance
Illustration
 Store the suction hose and the mains
cable as shown in the illustration.
 Place the appliance in a dry room and
secure it from unauthorized use.

Transport

CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
 Remove the suction pipe with the floor
nozzle from the holder. Hold the appli-
ance by the handle and at the suction
pipe to transport it, not by the push han-
dle.
 Pull the device behind you at the carry-
ing handle for transporting it over longer
distances
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
16
handle
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Care and maintenance

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Exchanging the flat pleated filter
 Open filter door.
 Replace the flat pleated filter.
 Close the filter door, it must lock into
place.
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.

Troubleshooting

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug,
the electrodes and possibly the recep-
tacle of the device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
– 4
EN

Storage

emptied