Top Vent Adapter Installation; Rear Vent Adapter Installations - Quadra-Fire OUTFITTER-II Installation Manual

Table of Contents

Advertisement

B. Top Vent Adapter Installation
3 to 3 inch Top Vent Adapter
3 to 6 inch Top Vent Offset Adapter
1. Put a layer of high temperature silicone on the 3 inch
(76mm) exhaust outlet. Do not put silicone inside of pipe
(Figure 22.1).
2. Slide the top vent adapter onto the rear exhaust outlet and
adjust the assembly to a vertical position (Figure 22.1).
3. Install the 4 mounting screws.
4. Drill 2 holes with #26 drill bit through the rear exhaust
outlet using the 2 holes already in the short horizontal
pipe in the top vent adapter as a guide. Install the 2
screws (Figure 22.1).
5. Install the vent pipe into the top vent adapter.
6. To clean the top vent adapter open the clean-out cover
(Figure 22.1).
Silicone Rear
Exhaust Outlet
Figure 22.1
22
3 to 6 inch
Offset Adapter
3 to 3 inch
Offset
Adapter
Use holes located on
each side a drilling guide
C. Rear Vent Adapter Installations
1. Put a layer of high temperature silicone on the 3 inch
(76mm) exhaust outlet. Do not put silicone inside of pipe
(Figure 22.1).
2. Slide the adapter onto the rear exhaust outlet and adjust
the assembly to the appropriate position.
3. Install the vent pipe into the adapter.
Figure 22.2 - Rear Vent Adapter (811-0620)
Clean-Out
Cover
Figure 22.3 - 90° Rear to Top Vent Adapter (TPVNT-6)
8105-803B
Rear Vent
Adapter
(811-0620)
Clean-Out Cover
Top Vent
Adapter
(TPVNT-6)
02/22

Advertisement