Quadra-Fire CASTILE-MBK-C Installation Manual

Quadra-Fire CASTILE-MBK-C Installation Manual

Castile-b pellet appliance
Hide thumbs Also See for CASTILE-MBK-C:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
CASTILE-B PELLET APPLIANCE
MODEL(S):
CASTILE-MBK-C
CASTILE-PMH-C
CASTILE-TWL-C
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, fire officials or authorities
having jurisdiction about restrictions, installation
inspection, and permits.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
R
If the information in these instructions is
not followed exactly, a fire could result
causing property damage, personal
injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void
your warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down. Hot glass will
cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as fireplace.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
To obtain a French translation of this manual, please contact
your dealer or visit
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez
7021-801B
WARNING
WARNING
CAUTION
NOTE
www.quadrafire.com
www.quadrafire.com
April 23, 2019

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire CASTILE-MBK-C

  • Page 1 MODEL(S): • Do not store or use gasoline or other flammable CASTILE-MBK-C vapors and liquids in the vicinity of this or any CASTILE-PMH-C other appliance. • Do not over fire - If appliance or chimney connector CASTILE-TWL-C glows, you are over firing.
  • Page 2: Table Of Contents

    F. Equivalent Feet of Pipe ..... .16 G. Pipe Selection Chart ......16 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7021-801B...
  • Page 3: Important Safety Information

    CASTILE FREESTANDING Important Safety Information A. Appliance Certification B. BTU & Efficiency Specifications Emissions Report Model Castile Pellet Appliance 0061PM077E Number: Laboratory OMNI Test Laboratories, Inc. EPA Certification #: 175-19 Report No. 061-S-77d-6.2 EPA Certified Emissions: 1.1 grams per hour Solid Fuel Room Appliance/Pellet Fuel Type *LHV Tested Efficiency: 70.4%...
  • Page 4: Glass Specifications

    CASTILE FREESTANDING C. Glass Specifications This appliance is equipped with 5mm ceramic glass. WARNING Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. Fire Risk. D. Electrical Rating Hearth & Home Technologies disclaims any 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps responsibility for, and the warranty will be voided by, the following actions: E.
  • Page 5: Getting Started

    CASTILE FREESTANDING Install Guide Getting Started A. Design, Installation & Location Considerations 1. Appliance Location Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: • Windows NOTICE: Check building codes prior to installation. • Air Intakes •...
  • Page 6: Thermostat Wall Control Location

    CASTILE FREESTANDING B. Thermostat Wall Control Location WARNING The thermostat wall control’s location will have some affect on the appliance’s operation. • Maximum wire length from appliance is 100 Risk of Fire! feet (30.48m) with continuous non-spliced wire. • Damaged parts could impair safe operation. Recommended 20 gauge wire, solid copper .
  • Page 7: Install Checklist

    CASTILE FREESTANDING E. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. __________________________________________________________________________ Customer: ______________________________________________________________________ Date Installed: _______________________________________________________________________ Lot/Address: ________________________________________________________________...
  • Page 8: Dimensions And Clearances

    CASTILE FREESTANDING Dimensions and Clearances A. Appliance Dimensions 11-7/8 in 11-7/8 in 5-3/4 in (302mm) (302mm) 3-1/2 in (146mm) (89mm) Figure 8.1 - Top View Figure 8.3 - Top View with TPVNT-6 and 811-0720 3 in 3-1/4 in (76mm) (83mm) 11-7/8 in (297mm) 3 in...
  • Page 9 CASTILE FREESTANDING 23-5/8 in (600mm) 9-1/2 in (241mm) 27 in 28-1/2 in (686mm) (724mm) 28-5/8 in (727mm) 15-1/2 in (394mm) Figure 9.4 - Side View with TPVNT-2 and 811-0720 24 in (610mm) Figure 9.1 - Front View 24-5/8 in (626mm) 22-7/8 in (581mm) 26-3/4 in...
  • Page 10: Clearances To Combustibles (Ul And Ulc)

    CASTILE FREESTANDING B. Clearances to Combustibles (UL and ULC) Installations with: 3 to 3 inch Top Vent Adapter and 3 to 6 inch Offset Adapter Kit Horizontal Through the Wall Inches Millimeters Back Wall to Appliance Vertical Installation Inches Millimeters Side Wall to Appliance Back Wall to Flue Pipe Corner Installation...
  • Page 11: Hearth Pad Requirements (Ul And Ulc)

    CASTILE FREESTANDING C. Hearth Pad Requirements (UL and ULC) USA INSTALLATIONS: A non-combustible floor protection is recommended extending beneath the flue pipe when EMBER PROTECTION: It is necessary to install a Type I installed with horizontal venting or under the Top Vent floor protector.
  • Page 12: Alcove

    CASTILE FREESTANDING D. Alcove Figure 12.1 Minimum* Maximum Inches Millimeters Inches Millimeters Height 1092 Width Depth To Side Wall *All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale.
  • Page 13: Vent Information

    CASTILE FREESTANDING Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Termination Cap Air Supply Inlet Gas Meter Restricted Area All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 14: Avoiding Smoke And Odors

    CASTILE FREESTANDING B. Avoiding Smoke and Odors Vent Configurations When installing a pellet appliance with a horizontal vent Negative Pressure, Shut-Down and Electrical Power configuration the frequency of power outages should be Failure considered: To reduce the probability of back-drafting or burn-back •...
  • Page 15: Negative Pressure

    3 to 6 inch (76-152mm) Top Vent Offset Adapter, • Combustion air requirements for furnaces, water use Listed double wall flue connector. A Quadra-Fire appliances and other combustion appliances Outside Air Kit must be used with manufactured home •...
  • Page 16: Equivalent Feet Of Pipe

    CASTILE FREESTANDING F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size (Figure 16.1). Vent surfaces get HOT, can cause burns if touched. Non-combustible shielding or guards may be required.
  • Page 17: Venting Systems

    Must use 3 or 4 inch (76-102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and a Quadra-Fire Outside Air Kit in mobile homes. NOTICE: Please note that while the minimum clearance for the termination cap is 6 inches (152mm)
  • Page 18: Vertical Into Existing Class A Chimney

    CASTILE FREESTANDING B. Vertical into Existing Class A Chimney We recommend a minimum of 60 inches (1524mm) vertical, however above the eave is preferred. Rain Cap All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and Quadra- Fire Outside Air Kit in mobile homes.
  • Page 19: Masonry

    CASTILE FREESTANDING E. Masonry Fireclay flue Concrete Cap liner with airspace Flashing 1 in. (25mm) clearance with firestop 1 in. (25mm) clearance 3 in. (76mm) minimum 6 in. (152mm) Sheathing minimum Clean-out cover Airtight Clean-out Door Non-combustible Hearth Pad Figure 19.1 F.
  • Page 20: Appliance Set-Up

    CASTILE FREESTANDING Appliance Set-Up A. Outside Air Kit Instructions 3. Secure air channel to appliance with 2 screws and secure the collar assembly to the air channel with 2 CAUTION screws (Figure 20.3). 4. Measure distance from floor to air vent opening in Never draw outside combustion air from: appliance and mark location on wall.
  • Page 21: Top Vent Adapter Installation

    CASTILE FREESTANDING B. Top Vent Adapter Installation C. Rear Vent & Rear Vent to Top Vent Adapter Installation 3 to 3 inch Top Vent Adapter 1. Put a layer of high temperature silicone on the 3 inch 3 to 6 inch Top Vent Offset Adapter (76mm) exhaust outlet.
  • Page 22 CASTILE FREESTANDING There is a 4 screw terminal block located on the back lower 1. Separate the body of the thermostat from the left corner of the appliance directly above the power cord mounting plate by gently pulling the two pieces apart inlet.
  • Page 23: Leg Leveling System

    CASTILE FREESTANDING E. Leg Leveling System F. Optional Log Set Placement Instructions 2 Piece Log Set Installation 1. Thread Allen bolts through nuts until flush 1. Open door to expose the firebox. (Figure 23.1). The Allen bolts and nuts are included in 2.
  • Page 24: Mobile Home Installation

    CASTILE FREESTANDING Mobile Home Installation You must use a Quadra-Fire Outside Air Kit for CAUTION installation in a mobile home. 1. An outside air inlet must be provided for the THE STRUCTURAL INTEGRITY OF THE MOBILE combustion air and must remain clear of leaves, debris, HOME FLOOR, WALL AND CEILING/ROOF MUST BE ice and/or snow.
  • Page 25: Reference Materials

    CASTILE FREESTANDING Reference Materials A. Service and Maintenance Log Date of Service Performed By Description of Service April 23, 2019 7021-801B...
  • Page 26 CASTILE FREESTANDING Date of Service Performed By Description of Service 7021-801B April 23, 2019...
  • Page 27: Accessory List

    CASTILE FREESTANDING B. Accessory List Castile-C Service Parts Beginning Manufacturing Date: April 2019 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 28 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafire.com CAUTION DO NOT DISCARD THIS MANUAL...

This manual is also suitable for:

Castile-pmh-cCastile-twl-c

Table of Contents