Venting Systems

A. Through The Wall
Horizontal termination cap must be a minimum of 6
inches. (152mm) from the wall. Approved for mobile home
installations. Must use 3 or 4 inch (76-102mm) "L" or "PL"
listed pellet venting or Listed double wall pipe and an
authorized Outside Air Kit in mobile homes.
NOTICE: Please note that while the minimum clearance
for the termination cap is 6 inches (152mm) there is the
possibility of soot build-up around the termination area.
If this occurs we suggest to move the termination further
away from the house to prevent it.
6 in.
(152mm)
Minimum
from glass
Figure 18.1 - Straight Out
Illustration shows venting going in both directions.
Choose which one is best for your installation.
Wall
Thimble
6 in
(152mm)
Minimum
3 in.
(76mm)
Minimum
Figure 18.2 - 45 Degree
18
3 in.
(76mm)
Minimum
Horizontal
Wall
Termination
Thimble
Cap
6 in.
(152mm)
Minimum
Non-combustible Hearth Pad
6 in (152mm) Minimum
3 in. (76mm)
Minimum
NOTE: In Canada, where passage through a wall or
partition of combustible construction is desired, the
installation shall conform to CAN/CSA-B365
We
strongly
DOWNWARD VENT.
The following may occur:
• The appliance will not vent properly
• Smoke spillage in the house
• Excessive sooting
8105-803B
CAUTION
recommend
that
you
DO
NOT
02/22