Fault
"Please empty con-
densate container"
and programme ter-
minated.
Condensation in the
condensation tank
even though the water
drain hose is connec-
ted.
The programme does
not start.
The length of the pro-
gramme changes dur-
ing the drying cycle.
Pumping noise.
Buzzing noise.
Cause and troubleshooting
Route the water drain hose without kinks.
2.
Water drain hose is not connected correctly.
Ensure that the water drain hose is connected cor-
rectly.
→ "Connecting the water drain hose", Page 14
Water drain hose is blocked.
Rinse the water drain hose with tap water.
The filter for the condensation tank is soiled.
→ "Clean the filter for the condensation tank.",
Page 58.
Foreign object is located in the base unit
→ "Opening the base unit", Page 55.
1.
Remove the foreign objects that are present.
2.
→ "Closing the base unit", Page 56.
3.
Dirt in the appliance.
→ "Preparing the appliance for the intensive appli-
ance care programme", Page 52.
The appliance uses condensation for the automatic
self-cleaning.
Not a fault – no action required.
Water drain hose is not connected correctly.
Ensure that the water drain hose is connected cor-
rectly.
→ "Connecting the water drain hose", Page 14
Childproof lock is activated.
→ "Deactivating the childproof lock", Page 40
You have not pressed Start/Reload .
Press Start/Reload .
No programme set.
→ "Setting a programme", Page 36.
1.
→ "Starting the programme", Page 37.
2.
The programme operation is optimised electronically.
This may change the programme duration.
Not a fault – no action required.
Condensation pump active.
Not a fault – normal operating noise.
Compressor ventilation active.
Not a fault – normal operating noise.
Troubleshooting en