DD+DIS303.03E
6.2
TYPE 5270/105
Edition 6, Revision 0
Classic E.O.S. CL Type 5270/105
The required floor space for the film processor in combination with the Laser
Imager LR3300, feed table, chute and the required clearance on the left is
1700 x 860 mm (66.98 x 33.88 inch).
In case of an installation of the Laser Imager LR3300 or another daylight
system observe the installation documentation enclosed with the machine.
The free space indicated in the illustration must be guaranteed for repair and
maintenance, otherwise the time required for service will increase.
Optimum dimensions:
We recommend to plan on this free space.
Minimum dimensions:
Do not go below this minimum space.
(A) Operation side
Dimensions in mm (inch)
Classic E.O.S. / Classic E.O.S. CL
(Type 5270 / 100 / 105)
400
(15.76)
1710 (67.37)
860 (33.88)
600 (23.64)
1000 (39.4)
Figure 6
Installation Planning
2710 (106.77)
1910 (75.25)
600
(23.64)
A
LR3300
5270_10001_005.cdr
A
Chapter 14 / 11
400
(15.76)