28
www.electrolux.com
• There must be a continuous air supply
around the oven in order to not have
the oven become too hot.
• For correct operation, the oven
cabinet must have a minimum
opening of 130 cm² in the front or on
the sides (a minimum of 65 cm² for
each side). The manufacturer
recommends a 130 cm² opening in
the front for a brick cabinet and a 65
cm² opening for each side for a
wooden cabinet.
• When you install a hob above the
oven, make different electrical
connections for the hob and for the
oven.
Only make connections with correct
cables for the power supplied.
Make sure that after the
installation there is easy
access to the appliance if
repairs or maintenance are
necessary.
12.6 Securing the appliance to
the cabinet

13. TECHNICAL DATA

13.1 Technical data
TOTAL POWER:
Electric supply:
A
B
Electric:
Gas original:
Gas replacement:
220 - 240 V ~ 50 / 60 Hz
12.7 Electrical installation
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
This appliance is supplied only with a
main cable.
12.8 Cable
Cable types applicable for installation or
replacement:
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
Total power (W)
maximum 1380
maximum 2300
maximum 3680
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
1.76 kW
G20 (2H) 20 mbar = 2.7 kW
G30/G31 (3B/P) 30/30 mbar = 2.7 kW
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5