3URGXFW 6SHFL¿F DQG ,PSRUWDQW 6DIHW\ ,QIRUPDWLRQ
$ $SSOLDQFH &HUWL¿FDWLRQ
MODEL: AVFL42NIP-BU, AVFL42PIP-BU, AVFL42NIP-RB,
AVFL42PIP-RB, AVFL48NIP, AVFL48PIP, AVFLST48NIP,
AVFLST48PIP, AVFL60NIP-B, AVFL60PIP-B
LABORATORY: UNDERWRITERS LABORATORIES, INC.
(UL)
TYPE: Unvented Room Heaters
STANDARD:
ANSI Z21.11.2:19
7KLV SURGXFW LV OLVWHG WR $16, VWDQGDUGV IRU 8QYHQWHG
5RRP +HDWHUV´ DQG DSSOLFDEOH VHFWLRQV RI *DV %XUQLQJ
+HDWLQJ $SSOLDQFHV IRU 0DQXIDFWXUHG +RPHV DQG *DV
)LUHG $SSOLDQFHV IRU 8VH DW +LJK $OWLWXGH
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
WDO URRP KHDW RU DV D GHFRUDWLYH DSSOLDQFH ,W VKRXOG QRW EH
IDFWRUHG DV SULPDU\ KHDW LQ UHVLGHQWLDO KHDWLQJ FDOFXODWLRQV
% %78 6SHFL¿FDWLRQV
Models
$9)/1,3%8 1*
(0-2000 FT)
$9)/3,3%8 3523$1(
(0-2000 FT)
$9)/1,35% 1*
(0-2000 FT)
$9)/3,35% 3523$1(
(0-2000 FT)
$9)/1,3 1*
(0-2000 FT)
$9)/3,3 3523$1(
(0-2000 FT)
$9)/671,3 1*
(0-2000 FT)
$9)/673,3 3523$1(
(0-2000 FT)
$9)/1,3% 1*
(0-2000 FT)
$9)/3,3% 3523$1(
(0-2000 FT)
NOTE: )RU /3 PRGHOV DQ H[WHUQDO UHJXODWRU LV UHTXLUHG
WR UHGXFH VXSSO\ SUHVVXUH WR D PD[LPXP RI  ZF
GAS PRESSURES
Inlet Minimum
Inlet Maximum
5HJXODWRU 3UHVVXUH
Setting
3LORW 5HJXODWRU
4
Maximum
Minimum
Input
Input BTU/h
BTU/h
34,000
23,500
 
33,000

24,500
17,500
24,000
19,000
 
39,000
27,500
38,000
31,000
39,000
27,500
38,000
31,000
40,000
28,000
39,000
30,500
NATURAL
PROPANE (LP)
 ZF
 ZF
 ZF
 ZF
 ZF
 ZF
 ZF
²
Monessen • AVFL Series Installation Manual • 4099-901 Rev. E • 01/22
C. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation: 5HGXFH LQSXW
UDWH 
IRU HDFK  IHHW DERYH  IHHW
Check with your local gas utility to determine proper
RUL¿FH VL]H
' 1RQ&RPEXVWLEOH 0DWHULDOV 6SHFL¿FDWLRQ
0DWHULDO ZKLFK ZLOO QRW LJQLWH DQG EXUQ 6XFK PDWHULDOV DUH
those consisting entirely of steel, iron, brick, tile, concrete,
VODWH JODVV RU SODVWHUV RU DQ\ FRPELQDWLRQ WKHUHRI
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
( &RPEXVWLEOH 0DWHULDOV 6SHFL¿FDWLRQ
Materials made of or surfaced with wood, compressed pa-
SHU SODQW ¿EHUV SODVWLFV RU RWKHU PDWHULDO WKDW FDQ LJQLWH
DQG EXUQ ZKHWKHU ÀDPH SURRIHG RU QRW RU SODVWHUHG RU
XQSODVWHUHG VKDOO EH FRQVLGHUHG FRPEXVWLEOH PDWHULDOV
2UL¿FH
F. Electrical Codes
Size (DMS)
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
 
absence of local codes, with National Electric Code
 
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
 
‡ $  9$& FLUFXLW IRU WKLV SURGXFW PXVW EH SUR-
 
tected with ground-fault circuit-interrupter protection,
in compliance with the applicable electrical codes,
 
when it is installed in locations such as in bathrooms
 
RU QHDU VLQNV
 
 
WARNING: This product and the
fuels used to operate this product (liquid
propane or natural gas), and the products
of combustion of such fuels, can expose
you to chemicals including benzene, which
is known to the State of California to cause
cancer and reproductive harm. For more
information go to: www.P65Warnings.
ca.gov.