E. Valve Access
The valve and controls are located in the appliance con-
WURO DUHD 6HH )LJXUH 
The controls area can be accessed by lifting engine as-
VHPEO\ DV VKRZQ LQ )LJXUH 
0DNH VXUH DSSOLDQFH LV R DQG FRRO
5HPRYH FUXVKHG JODVV PHGLD DQG GHÀHFWLRQ JODVV
SDQHO IURP KHDUWK SDQ
5HPRYH WZR  VFUHZV VHFXULQJ EXUQHU DVVHPEO\ WR
DSSOLDQFH VHW DVLGH
Lift the burner assembly and place the two engine
supports, provided under the engine, against lower
front space at the bottom of the face, and slide into
WKH VORWV DW WKH ERWWRP RI WKH HQJLQH DVVHPEO\ 6HH
)LJXUH 
/RFDWH YDOYH RQ IDFH RI HQJLQH DVVHPEO\
*DV OLQH VL]LQJ UHTXLUHPHQWV ZLOO EH GHWHUPLQHG LQ
$16, = 1DWLRQDO )XHO *DV &RGH LQ WKH 86$
Pressure requirements are:
7KHVH SUHVVXUHV FDQ EH YHUL¿HG E\ OLIWLQJ HQJLQH DQG
UHPRYLQJ FRQWURO FRYHU WR UHYHDO WKH YDOYH
:KHQ DQ DSSOLDQFH LV FRQQHFWHG WR D ¿[HG SLSLQJ V\V-
tem, the installation must conform with local codes,or in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or International Fuel Gas
Code.
Engine Support
Control Area
Figure 5.4 - Valve Access
24
Monessen • AVFL Series Installation Manual • 4099-901 Rev. E • 01/22
F. Check Gas Pressure
Check the gas pressure with the appliance burning and
the control set to HIGH
The valve regulator controls the burner pressure which
VKRXOG EH FKHFNHG DW WKH SUHVVXUH WHVW SRLQW
Turn captured screw counterclockwise two or three turns
DQG WKHQ SODFH WXELQJ WR SUHVVXUH JDXJH RYHU WHVW SRLQW
8VH WHVW SRLQW ³$´ FORVHVW WR JDV LQOHW $IWHU WDNLQJ SUHV-
sure reading, be sure and turn captured screw clockwise
¿UPO\ WR UHVHDO 'R QRW RYHU WRUTXH &KHFN IRU JDV OHDNV
6HH )LJXUH 
TEST PORT 'A'
Figure 5.5 - Pressure Test Point Location
Figure 5.6 - Gas and Electrical Access - Remove Screen
Screen