Finishing

A. Facing and Finishing Instructions
WARNING! Risk of Fire! Comply with all minimum clear-
DQFHV WR FRPEXVWLEOHV DV VSHFL¿HG )UDPLQJ FORVHU WKDQ WKH
minimums listed must be constructed entirely of non-com-
bustible materials (i.e., steel studs, concrete board, etc.).
Finishing Instructions
,W LV LPSRUWDQW WR IROORZ WKH IUDPLQJ DQG ¿QLVKLQJ LQVWUXF-
tions to ensure proper placement of appliance into the
VXUURXQGLQJ IUDPLQJ¿QLVKLQJ PDWHULDOV
:DOO VKHDWKLQJ PDWHULDOV  LQ WKLFN DUH VSHFL¿HG LQ
this installation manual to properly align with the non-
FRPEXVWLEOH PDWHULDO
WARNING! Risk of Fire! Non-combustible board MUST
be installed. DO NOT remove or cover it with combustible
material, such as:
• Drywall (gypsum board)
• Plywood
• Materials that do not meet the ASTM E 136 Non-com-
bustibility standard (below).
Removal of installed, non-combustible board and/or use
of materials not meeting the ASTM E 136 standard could
FDXVH ¿UH
1RQ&RPEXVWLEOH 0DWHULDOV 6SHFL¿FDWLRQ
0DWHULDO ZKLFK ZLOO QRW LJQLWH DQG EXUQ 6XFK PDWHULDOV DUH
those consisting entirely of steel, iron, brick, tile, concrete,
VODWH JODVV RU SODVWHUV RU DQ\ FRPELQDWLRQ WKHUHRI
2U PDWHULDOV WKDW DUH UHSRUWHG DV SDVVLQJ ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC.
WARNING! Risk of Fire! 0DLQWDLQ VSHFL¿HG DLU VSDFH
clearances to combustibles. Inadequate air space could
FDXVH RYHUKHDWLQJ DQG ¿UH
Finishing Materials
NOTICE: 7KH PD[LPXP ¿QLVKLQJ PDWHULDO QRW RQO\ LQFOXGHV
WKH GHFRUDWLYH ¿QLVK PDWHULDOV PDUEOH WLOH VODWH HWF EXW
also the thin set, lath, and adhesive used to attach the
GHFRUDWLYH ¿QLVK PDWHULDO
NOTICE: Surface temperatures around the appliance will
become warm while the appliance is in operation. Ensure
finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190°F.
This section discusses installation details associated
ZLWK WKH ,QVLGH DQG 2YHUODS )LW PHWKRGV DQG VSHFL¿HV
DGGLWLRQDO QRQFRPEXVWLEOH PDWHULDOV UHTXLUHG
7KH DSSOLDQFH LV GHVLJQHG WR PDWH ZLWK  LQ ZDOO
sheathing materials such as drywall, plywood, wood
FRPSRVLWHV RU QRQFRPEXVWLEOH PDWHULDOV

Monessen • AVFL Series Installation Manual • 4099-901 Rev. E • 01/22
• Finishing Around Perimeter of Appliance (Install
Option #1)
*\SVXP ZDOOERDUG GU\ZDOO MRLQWV FDQ EH ¿QLVKHG XS WR
the perimeter of the left, right and bottom edge of the
DSSOLDQFH ÀXVK ZLWK WKH IDFH 7KH  RI VXSSOLHG QRQ
combustible must be used at the top of the appliance
ZKHUH WKH J\SVXP ERDUG FDQ WKHQ EH ¿QLVKHG WR WKH OHIW
ULJKW DQG WRS HGJH RI WKH QRQFRPEXVWLEOH ERDUG
• Finishing Around Opening of Appliance (Install
Option #2)
127( :LWK WKLV LQVWDOODWLRQ RSWLRQ WKH DSSOLDQFH PXVW
be recessed to the depth of the non-combustible being
XVHG WR HQVXUH ¿QLVK LV ÀXVK ZLWK VXUURXQGLQJ ZDOO 7KLV
LV WKH UHFRPPHQGHG LQVWDOO RSWLRQ IRU DOO ¿QLVK NLWV VKRZQ
RQ SDJH  5HIHU WR 7ULP .LW LQVWUXFWLRQV IRU 2SWLRQ 
LQVWDOODWLRQ EHIRUH VWDUWLQJ
7KH  QRQFRPEXVWLEOH PXVW ¿UVW EH LQVWDOOHG DERYH
WKH XQLW LQ WKH VDPH PDQQHU DV LQVWDOODWLRQ RSWLRQ 
ÀXVK ZLWK WKH WRS IDFH RI WKH XQLW ,Q WKLV RSWLRQ QRQ
combustible is required for all material covering the face
RI WKH XQLW 7KH QRQFRPEXVWLEOH PD\ EH LQVWDOOHG XS WR
WKH ¿UHER[ RSHQLQJ EXW PXVW QRW RYHUODS ZKLFK ZRXOG
LPSHGH WKH UHPRYDO RI WKH VFUHHQ :KHQ LQVWDOOLQJ
PDWHULDO DURXQG WKH ¿UHER[ RSHQLQJ LQVWDOO WKH VKHHW
ZLWK D SUHFXW KROH IRU WKH ¿UHER[ RSHQLQJ LQ D VLQJOH
VKHHW LI SRVVLEOH 7KLV ZLOO PLQLPL]H MRLQWV DFURVV WKH
DSSOLDQFH IDFH DQG UHGXFH FUDFNLQJ
Tape wall board joints around the appliance opening with
¿EHUJODVVPHVK WDSH ,W ZLOO SURYLGH D PRUH FUDFNUHVLV-
WDQW MRLQW WKDQ SDSHU WDSH )LOO VPRRWK DQG ¿QLVK ZDOO
MRLQWV ZLWK FKHPLFDOO\ VHWWLQJW\SH MRLQW FRPSRXQG ,W ZLOO
provide a more crack-resistant joint than air-drying light-
ZHLJKW FRPSRXQG
Finish and Sealing Joints
$OO MRLQWV EHWZHHQ WKH ¿QLVKHG ZDOO VKHDWKLQJ DQG WKH DS-
SOLDQFH PXVW EH VHDOHG ZLWK QRQFRPEXVWLEOH PDWHULDOV
Sealants, such as caulk or mastic used to seal the gap
between the wall and the appliance, should be rated at a
PLQLPXP FRQWLQXRXV H[SRVXUH WR ž)
Painting
,I GHVLUHG ¿QLVKLQJ LQFOXGHV D SDLQWHG ZDOO 
latex with compatible primer is recommended around this
DSSOLDQFH 2LOEDVHG RU VWDQGDUG DFU\OLF SDLQWV PD\ GLV-
FRORU GXH WR KHDW H[SRVXUH