Siemens SIMOTION TM15 Commissioning Manual page 53

Terminal modules
Hide thumbs Also See for SIMOTION TM15:
Table of Contents

Advertisement

Error codes
Table 4- 1
ERROR CODE 35...
...801 to
...905
...906
...907
The error code (see table above) is stored as parameter P2122 in the SINAMICS Control
Unit. This code can be read by the user task with the "readDriveParameter" system function
(see SIMOTION documentation "Reference List – System Functions / Variables").
Another option is to use the BICO technology editor to link parameter P2122 with an I/O
word that has been added to one of the axis message frames of the SINAMICS Control Unit.
This enables cyclic reading of the error code.
TM15 / TM17 High Feature Operating Manual
Commissioning Manual, 05/2009
Error codes (for hotline)
BITS
MF
PS
FPGA
DESCRIPTION
Internal module error
or
communication problem
on DRIVE CLiQ
interface
At least one of the
terminals for the I/O
power supply is not
connected
or
the I/O power supply is
outside of the specified
range.
If the error is no longer
present, the error code
is retracted
automatically.
FPGA programming
error (TM17 High
Feature only)
Error messages
REMEDY
Replace the module
and contact your local
technical support.
Check all terminals for
the I/O power supply.
Try to update the
firmware.
If error is still present,
replace the module and
contact your local
technical support.