Stanley SOLIS K100 Installation And Operating Instructions Manual page 25

Wood pellet stoves
Table of Contents

Advertisement

Alarm
Code
Lack of voltage
Er15
supply
Communication
Er16
error RS485
Open door error
Er44
(First Advance
12kW
only)
Service
Service Maximum Hours:
THE MAINTENANCE FAULT ("SERVICE" MESSAGE ON THE DISPLAY) MEANS
THAT THE STOVE HAS MORE THAN 2100 HOURS IN SERVICE. THE CUSTOMER
MUST HAVE THE EQUIPMENT SERVICED AND ONLY THEN RESET THE HOUR
METER TO ELIMINATE THE FAULT MESSAGE. THIS DOES NOT INFLUENCE THE
NORMAL OPERATION OF THE EQUIPMENT; IT IS ONLY A WARNING.
Lack of voltage
supply
for more than 50 min
Door opens for 60
sec
2100 hr
(T66) planned for
maintenance achieved
Troubleshooting
- Check supply voltage with your
electricity supplier
- Check the simultaneous use of
electrical appliances
- In the event of a short power
failure (<10s) the stove continues
to operate normally
- If the system was in the ON state
and the power failure occurs for
more than 10s and less than 50
min, the stove will switch on after
blackout
- Check connection between board
and display
- Close the door - remove the error
- Air mass sensor damage
- Contact your installer for
occasional preventive maintenance
of the equipment