Control And Display Panel - Stanley SOLIS K100 Installation And Operating Instructions Manual

Wood pellet stoves
Table of Contents

Advertisement

When first connected the display indicates the "OFF" status of the stove,
it can also indicate the chrono activation, system errors, selected combustion power,
selected ventilation power, current room temperature and selected room temperature
set-point.
While in the Home Page by pressing the key:
"P1" is used to exit the menu/submenu;
"P2" is used to switch on the equipment, or, switch off the equipment. The
same button allows the errors reset, by pressing 3 seconds continuously, it also
allows the activation of Chrono in the corresponding submenu;
"P3" is used to access the user menu 1,
"P3" when held for 3 seconds is used to access the user menu 2,
"P4" is used to enter the Combustion Power menu;
"P5" is used to enter the Information menu and also activate a Chrono time slot;
"P6" is used to enter the Room Thermostat menu;
"P3" + "P5" for 3 seconds it is possible to access the secondary information menu
present in the service menu where it is possible to check a set of variables.
Warning
THE STOVE MUST ALWAYS BE DEACTIVATED IN THE SAME WAY IT WAS ACTI-
VATED. THE EQUIPMENT
MUST NEVER BE UNPLUGGED DURING THE ACTIVATION PROCESS.