Panasonic INDUSTRY LS-400 Series Manual page 4

Amplifier-separated digital laser sensor
Hide thumbs Also See for INDUSTRY LS-400 Series:

Advertisement

4
Digital Laser Sensor
Easy setting, dual display
Equipped with 2 large 4-digit digital displays. While checking the current incident light intensity (red display), the
optimal threshold value (green display) can be set easily.
10 mm
2 switches enable simple operation
Only two switches, the large MODE key and the large jog switch, are required for operation.
1
Pressing the switch
selects or cancels the
operating mode
Wiring and space saving
The quick-connection cables enable reductions in wiring.
(connector type)
The connections and man-hours for the relay terminal
setup can be reduced and valuable space is saved.
Also, LS-400 series amplifiers can of course be
connected side-by-side with a connector type amplifier
of FX-500/300 series digital fiber sensors or DPS-400
series digital pressure sensors.
Note: Because the transmission method varies depending on the
amplifiers, check the instruction manual for the amplifiers when
connecting them.
New release of type with upper communication functions to facilitate preventive maintenance!
Network communication possible
Can connect to Open Network CC-Link IE Field /
CC-Link / DeviceNet / EtherCAT via Communication
Unit for Open Network SC-GU3 series. Monitoring and
various settings can be done from PLC, PC, etc.
Current values
of connected
sensors are
shown.
し きい値
現在値
し きい値
1ch
90
65
9ch
2ch
50
0
10ch
3ch
40
70
11ch
4ch
0
0
12ch
5ch
0
0
13ch
6ch
0
0
14ch
7ch
0
0
15ch
8ch
0
0
16ch
[Touch panel display example]
Threshold values of
connected sensors are
shown.
Communication Unit
for Open Network
SC-GU3 series
LS-400
SERIES
0.394 in
thickness
Threshold value setting display
Green LED, 4 digits (Max. display: 9999)
2
現在値
0
0
0
0
End unit
0
0
0
0
0
0
0
0
0
0
0
0
Digital laser sensor
Digital fiber sensor
Digital fiber sensor
Digital pressure sensor
Current incident light intensity display
Large jog switch
Red LED, 4 digits (Max. display: 9999)
Moving the switch from
side to side allows items
to be selected
Digital fiber sensor
FX-500/300 series
Digital pressure sensor
DPS-400 series
Note: Because the transmission method varies depending on the
amplifiers, check the instruction manual for the amplifiers when
connecting them.
Threshold tracking function saves
maintenance time
This function seeks
changes in the light emitting
amount resulting from
changes in the environment
over long periods (such
as dust levels), so that
the incident light intensity
can be checked at desired
intervals and the threshold
values can be reset
automatically. This helps to
reduce the man-hours for
maintenance.
* C C-Link and CC-Link IE Field are a registered trademark of
LS - 403/501
Mitsubishi Electric Corporation.
FX - 501/502
DeviceNet is a registered trademark of ODVA (Open DeviceNet
FX - 301/305
Vender Association, Inc.).
DPS - 401/402
EtherCAT is a registered trademark of Beckhoff Automation GmbH.
Large MODE key
3
Pressing the switch then
confirms the selected
setting
Up to 16 units can be
connected together

LS-403
Current value
The amount of light
received when there
is no object
Threshold value
Time