OPERATOR'S MANUAL
This manual provides information on
installation, operating, maintenance,
trouble shooting & replacement parts for
PIZZA HUT MAKETABLE
PH120F
PH96F
NOTIFY CARRIER OF DAMAGE AT ONCE.
It is the responsibility of the consignee to inspect the
container upon receipt of same and to determine the
possibility of any damage, including concealed
damage. Randell suggests that if you are suspicious
of damage to make a notation on the delivery receipt.
It will be the responsibility of the consignee to file a
claim with the carrier. We recommend that you do so
at once.
525 South Coldwater Rd • Weidman, MI 48893
888-994-7636 • Fax 888-864-7636 • unifiedbrands.net
3/14/2018
PP MNL1706 rev A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Unified Brands Randell PH120F and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dover Unified Brands Randell PH120F

  • Page 1 OPERATOR’S MANUAL This manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for PIZZA HUT MAKETABLE PH120F PH96F NOTIFY CARRIER OF DAMAGE AT ONCE. It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage.
  • Page 3 Table of Contents page 2………………………………….…………Congratulations page 3……………………………………Parts & Service Hotline page 3………………………………...…Serial Number Location page 4-7……………………………….Randell Limited Warranty page 8…………………………………………Unit Specifications page 9-10…………………………………………Unit Installation page 11-12...……………………………………...Unit Operation page 13-15………………………………….Rail Cleaning Guide page 16-18……………………………..Preventive Maintenance page 18………………………………………..Electrical Diagram page 19……………………………………..……Troubleshooting page 20-27………………..………………... Exploded Drawings page 28-29………………………………Replacement Parts List Congratulations on your recent purchase of Randell food service equipment, and welcome to the growing family of satisfied Unified Brands customers.
  • Page 5 In addition, all Randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians. Retain this manual for future reference. NOTICE: Due to a continuous program of product improvement, Unified Brands reserves the right to make changes in design and specifications without prior notice.
  • Page 6: Warranty Policies

    Warranty Policies Unified Brands believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit is the peace of mind that this unit has been thoroughly engineered, properly tested and manufactured to excruciating tolerances, by a manufacturer with over 30 years of industry presence.
  • Page 7 with proof of starting date, up to a maximum of six months from date of purchase. Temperature adjustments are not covered under warranty, due to the wide range of ambient conditions. To inquire if the equipment is within warranty, call our Field Service Department at: 1-88-994-7636.
  • Page 8 the unlimited number of customer related circumstances that can cause gasket failure all gasket replacement issues are considered non- warranty. Unified Brands recommends thorough cleaning of gaskets on a weekly basis with a mild dish soap and warm water. With proper care Randell gaskets can last up to two years, at which time we recommend replacement of all gaskets on the equipment for the best possible performance.
  • Page 9: Returned Goods

    Brands will not be held responsible for any carrier rate differences; rate differences are entirely between the carrier and purchaser. Point of shipping shall be determined by Unified Brands (Weidman, MI/Jackson, MS). dealer’s request, Unified Brands will endeavor whenever practical to meet dealer’s request.
  • Page 10: Unit Specifications

    Unit Specifications Work Ref/ Ship Model Doors H.P. Voltage Amps NEMA Hgt. R404a/40oz PH96F 96” 40”* 55”** 35” (3) 24” ¾ 115/60/1 5-20P 980lb R404a/40oz PH96F-SS 96” 40”* 55”** 35” (3) 24” ¾ 115/60/1 5-20P 980lb R404a/40oz PH120F 120” 40”* 55”** 35”...
  • Page 11: Unit Installation

    Unit Installation SELECTING A LOCATION FOR YOUR NEW UNIT The following conditions should be considered when selecting a location for your unit: Floor Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit plus the maximum product load weight (PH120F) max floor load = 1870 lbs.).
  • Page 12 Unit Installation (con’t.) ELECTRICAL SUPPLY: The wiring should be done by a qualified electrician in accordance with local electrical codes. A properly wired and grounded outlet will assure proper operation. Please consult the data tag attached to the compressor to ascertain the correct electrical requirements. Supply voltage and amperage requirements are located on the serial number tag located inside the mechanical housing.
  • Page 13: Unit Operation

    Unit Operation MORNING STARTUP 1. Rail cleaning may be performed at this time. 2. Turn on the rail with the switch located on the front mechanical panel of the unit. 3. Allow 45 minutes to one hour for your unit to cool down before loading product.
  • Page 14 Unit Operation (con’t.) To raise temperature in the refrigerated rail: A. Push and hold the “set” button until 33 appears then release the “set” button. 33 is the current set point temperature. B. Push and release the up arrow 2 times until 35 is displayed. Push and release the “set”...
  • Page 15 Rail Cleaning Guide The Randell Maketable refrigerated condiment rail compartment is provided with a clean out drain. It is recommended that this compartment is cleaned daily. Estimated time to clean the rail compartment is 15 minutes. Note: Never use bleach or other harsh chemicals in cleaning the prep rail.
  • Page 16 The Maketable also has 2 additional drains for evaporator coil condensation located behind the front and rear wall panels of the refrigerated rail compartment. The refrigerated rail is designed to minimize food spillage from entering the evaporator coil area. It is recommended that the panels located in the front and back wall be removed quarterly by an authorized service agent to clean any spillage that may occur in this area;...
  • Page 17 Figure A Figure B Figure C Figure D Figure E Figure F Figure G Figure H unifiedbrands.net...
  • Page 18: Preventive Maintenance

    Preventive Maintenance Randell strongly suggests a preventive maintenance program which would include the following Monthly procedures: 4. Cleaning of all condenser coils. Condenser coils are a critical component in the life of the compressor and must remain clean to assure proper air flow and heat transfer.
  • Page 19: Cleaning Agent

    Preventive Maintenance (cont.) RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING: CLEANING AGENT COMMENTS Soap, ammonia, detergent Routine cleaning Apply with a sponge or cloth Medallion Fingerprints and smears Arcal 20, Lac-O-Nu, Ecoshine Provides a barrier film Stubborn stains and Cameo, Talc, Zud, First Rub in the direction of the discoloration...
  • Page 20: Electrical Diagram

    Electrical Diagram 888-994-7636...
  • Page 21: Troubleshooting Guide

    Trouble Shooting Guide SYMPTOM POSSIBLE CAUSE PROCEDURE Unit doesn’t run 1. No power to unit 1. Plug in unit 2. Temperature control turned off 2. Check temperature control 3. Temperature control faulty 3. Test temperature control 4. Compressor overheated 4. Clean condenser coil 5.
  • Page 22 Pizza Hut Maketable Replacement PH120F / PH96F Parts Unit Exterior 888-994-7636...
  • Page 23 Pizza Hut Maketable Replacement PH120F / PH96F Parts Refrigerated Rail Top Section unifiedbrands.net...
  • Page 24 Pizza Hut Maketable Replacement PH120F / PH96F Parts Condensing Unit Door and Shelf Components 888-994-7636...
  • Page 25 Pizza Hut Maketable Replacement PH120F / PH96F Parts Coil Assembly unifiedbrands.net...
  • Page 26: Replacement Parts List

    Pizza Hut Maketables Replacement PH120F / PH96F Parts List ITEM DESCRIPTION PART # Hood Assy Complete – PH120 models PH HOD0101 Hood Assy complete – PH96 models PHHOD1300 Lid for Rail Hood, 38” x 13 ½” – PH120 models PH HOD038 Lid for Rail Hood, –...
  • Page 27 Refrigeration Valve for Base Coil Assembly RF VLV414 Refrigeration Valve for Rail Coils RF VLV404 Evaporator Coil Assembly RP CSY1103 Evaporator Coil RF COI107 Solenoid Valve for Base / Rail RF SOL9801 Shield Panel for Base Coil Assembly RP PNL107 Evap coil housing –...