MULTI-DECK MERCHANDISER
INSTALLATION & OPERATIONS MANUAL
(AGED) CHEESE/MEAT
Technical Reference ...........................................2-5
General Information ............................................... 6
Installation ..........................................................7-8
Case Connections .................................................. 9
Lighting & Power Supplies ............................. 10-11
To ensure proper functionality and optimum performance, it is STRONGLY recommended that Hillphoenix specialty cases be installed/serviced by qualifi ed tech-
nicians who have experience working with commercial refrigerated display merchandisers and storage cabinets. For a list of Hillphoenix-authorized installation/
service contractors, please visit our website at www.hillphoenix.com.

Table of Contents

Pre-Power Checklist ............................................12
Airfl ow & Defrost ..................................................13
Case Cleaning ................................................ 14-15
Parts Ordering ......................................................16
Appendices
AGB-RG
08/21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hillphoenix AGB-RG and is the answer not in the manual?

Questions and answers

Summary of Contents for Dover Hillphoenix AGB-RG

  • Page 1: Table Of Contents

    MULTI-DECK MERCHANDISER INSTALLATION & OPERATIONS MANUAL AGB-RG (AGED) CHEESE/MEAT Table of Contents Technical Reference ...........2-5 Pre-Power Checklist ..........12 General Information ..........6 Airfl ow & Defrost ..........13 Installation ............7-8 Case Cleaning ..........14-15 Case Connections ..........9 Parts Ordering ............16 Lighting &...
  • Page 3 LIABILITY NOTICE For Cases with Shelf Lighting Systems Hillphoenix does NOT design any of its shelf lighting systems or any of its display cases with shelf lighting systems for direct or indirect exposure to water or other liquids. The use of a misting system or water hose on a display case with a shelf lighting system, resulting in the direct or indirect exposure of the lighting system to water, can lead to a number of serious issues (including, without limitation, electrical failures, fi...
  • Page 4 Important ® t Hillphoenix , the safety of our customers and employees, as well as the ongo- ing performance of our products, are top priorities. To that end, we include impor- tant warning messages in all Hillphoenix installation and operations handbooks, accompanied by an alert symbol paired with the word "DANGER", "WARNING", or "CAUTION".
  • Page 5 Revision History • new manual format_08/21...
  • Page 6: Technical Reference

    TECHNICAL REFERENCE Service Multi-Deck Merchandiser w/ Rear Load Doors AGB-RG 4', 6' & 8' (Cheese/Meat) GENERAL NOTES: • "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time. •...
  • Page 7 TECHNICAL REFERENCE Service Multi-Deck Merchandiser w/ Rear Load Doors AGB-RG 4', 6' & 8' (Cheese/Meat) ELECTRICAL DATA High Efficiency Anti-Condensate Drain Optional Defrost Fans Fans Heaters Heaters Humidification Fans 120 Volts 120 Volts 120 Volts 208 Volts 120 Volts Case Length Case Amps...
  • Page 8 TECHNICAL REFERENCE Service Multi-Deck Merchandiser w/ Rear Load Doors AGB-RG 4', 6' & 8' (Cheese/Meat) GUIDELINES AND CONTROL SETTINGS (GLYCOL) BTUH/ft Supply Temp Flow Rate Charge Cut-In Temp Cut-Out Temp (°F) (GPM/ft) (GAL/ft) (°F) (°F) Conventional Parallel Gravity Coil Serpentine DEFROST CONTROLS Electric Defrost Timed-Off Defrost...
  • Page 9 TECHNICAL REFERENCE Service Multi-Deck Merchandiser w/ Rear Load Doors AGB-RG 4', 6' & 8' (Cheese/Meat) SLIDING VERTICAL LIGHTING SLIDING 30" [76.2 cm] VERTICAL LIGHTING 36" [91.4 cm] REAR LOAD DOORS REAR LOAD DOORS 26" 20" 20" 26" 20 7/16" [51.9 cm] 26 7/16"...
  • Page 10: General Information

    GENERAL INFORMATION hank you for choosing Hillphoenix for your food merchandising needs. This handbook contains important technical information and will assist you with the installation and operation of your new Hillphoenix specialty cases. By closely following the instructions, you can expect peak performance; attractive fit and finish; and long case life. We are always interested in your suggestions for improvements (e.g.
  • Page 11: Installation

    CASE INSTALLATION LOCATION over time. 7. Locate vertical (bullet leg) support positions along the This refrigerated display case has been designed for displaying chalk line (Fig. 1). Spot properly leveled shim packs at and storing perishable food product. It is engineered for air- each support location.
  • Page 12 CASE INSTALLATION between the wall and back of case. Using a “J” bar, raise 5. Install the bumper, if applicable, into pre-attached bumper the end of the case (under cross support), and lower the track and snap into place. vertical support on to the shim packs. Repeat on the other 6.
  • Page 13: Case Connections

    CASE CONNECTIONS REFRIGERATION drains must be trapped. Before operating the case, be certain to remove the styrofoam Refrigeration connections will be made through the refrigera- tion stub up location on the customer left side of the case. shipping block that protects the plumbing lines during ship- Refrigeration lines may be headed together for all cases in a ping.
  • Page 14: Lighting & Power Supplies

    LIGHTING & POWER SUPPLIES GENERAL LIGHTING INFORMATION need for any signifi cant maintenance for several years. Should a power supply need to be removed and/or replaced, turn off the power to the case before proceeding. Be certain to replace Hillphoenix cases are equipped with LED luminaires and fea- ture specially designed light reflectors in the cornice to improve the power supply with genuine Hillphoenix parts or a compa- rable UL-listed Class-2 rated regulated 24V DC power supply...
  • Page 15 LIGHTING & POWER SUPPLIES ▲ C A U T I O N Too much tension on the inner clamp rings while removing them from an LED light rod may cause breakage. Use only enough tension for removal. Fig. 8 Closed clamp Fig.
  • Page 16: Pre-Power Checklist

    PRE-POWER CHECKLIST Before powering-up the case, be certain that all of the steps listed below have been completed to ensure proper case functionality, safety and compliance with warranty terms. Have you thoroughly examined the case for shipping damage? (see pg. 6) Have you checked the vertical plumb of the case? The horizontal level? (see pg.
  • Page 17: Airflow & Defrost

    AIRFLOW & DEFROST HUMIDIFICATION SYSTEMS AIRFLOW & PRODUCT LOAD The starting point for proper humidity levels in the AGB display Hillphoenix cases provide maximum product capacity within the case are typically around 75% RH when stocked with product. refrigerated air envelope. Please keep products within the ap- propriate load limit.
  • Page 18: Case Cleaning

    CASE CLEANING CASE CLEANING Rear Load & Lower Storage Doors 1. Remove the rear sliding doors on the back of the case A periodic cleaning schedule should be established to maintain and clean. To remove: push up and pull out (Fig. 12). proper sanitation, insure maximum operating efficiency, and Note: The same applies for optional lower storage doors avoid the corrosive action of food fluids on metal parts that are...
  • Page 19 CASE CLEANING THIS DOCUMENT CONTAINS IMPORTANT INFORMATION ABOUT ® CLEANING YOUR ULTRAVISION ANTI-REFLECTIVE GLASS! PLEASE READ AND FOLLOW THESE INSTRUCTIONS TO PREVENT DAMAGE TO THE ANTI-REFLECTIVE COATINGS. ® SOVIS ULTRAVISION tempered glass specialized Anti-Reflective coatings on each surface of the glass. These coatings reduce the glare from lighting so that the products on display are more visible to your customers.
  • Page 20: Parts Ordering

    PARTS ORDERING Contact the Service Parts Department at: 1-844-HPX-PART (1-844-479-7278) dfr-ia-parts@doverfoodretail.com Provide the following information about the part you are ordering: • Model number and serial number* of the case for which the part is intended. • Length of the part (if applicable). •...
  • Page 21 APPENDIX A1 ....................Wiring Information B1 ..............Sporlan Pressure-Temperature Chart C1 ........................Parts List...
  • Page 22 A1: WIRING DIAGRAM...
  • Page 23 B1: SPORLAN PRESSURE-TEMPERATURE CHART...
  • Page 24 C1: PARTS LIST Case Top Upper Front Panel Fixed Front Glass Lower Front Panel Front Toekick End Panel Trim End Panel Fixed End Glass End Toekick Outside Back Dry Lower Storage Bottom Deck SS Wire Riser Rear Load Doors Stainless Steel Wire Shelf Adjustable Shelf Bracket Inside Back Upper-Interior Wire Grid...
  • Page 25 Hill PHOENIX, Inc. Hereinafter Referred To As Manufacturer LIMITED WARRANTY GENERAL WARRANTY Manufacturer’s products are warranted to be free from defects in materials and workmanship under normal use and maintenance for fourteen months from date of shipment from manufacturer (the “Base Warranty Period”). In the event of a qualifying warranty claim, a new or rebuilt part to replace any defective part will be provided without charge.
  • Page 26 Warning Maintenance & Case Care When cleaning cases the following must be performed PRIOR to cleaning: To avoid electrical shock, be sure all electric power is turned off before cleaning. In some installations, more than one switch may have to be turned off to completely de-energize the case.