Download Print this page
Dover unified brands groen BPM-15E Operator's Manual
Dover unified brands groen BPM-15E Operator's Manual

Dover unified brands groen BPM-15E Operator's Manual

Domestic eclipse ergonomic tilting braising pan

Advertisement

Quick Links

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
MODELS BPM-15/30/40E
& BPP-30/40E
ECLIPSE™ ERGONOMIC
TILTING BRAISING PAN
· Stainless Steel
· Manual or Power Tilt
· Electrically Heated
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER 148727, REV. E (04/13)
Domestic
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net

Advertisement

loading
Need help?

Need help?

Do you have a question about the unified brands groen BPM-15E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dover unified brands groen BPM-15E

  • Page 1 OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: MODELS BPM-15/30/40E & BPP-30/40E Domestic ECLIPSE™ ERGONOMIC TILTING BRAISING PAN · Stainless Steel · Manual or Power Tilt · Electrically Heated THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
  • Page 2 IMPORTANT - READ FIRST - IMPORTANT CAUTION: BE SURE OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING INSTRUCTIONS, CAUTIONS, AND SAFETY INSTRUCTIONS IN THIS MANUAL. WARNING: THIS UNIT IS INTENDED FOR USE IN THE COMMERCIAL HEATING, COOKING AND HOLDING OF WATER AND FOOD PRODUCTS, PER THE INSTRUCTIONS CONTAINED IN THIS MANUAL.
  • Page 3 IMPORTANT - READ FIRST - IMPORTANT WARNING: BE CAREFUL TO AVOID CONTACT WITH CLEANING PRODUCTS IN ACCORDANCE WITH SUPPLIER AND MANUFACTURER RECOMMENDATIONS. MANY CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS MEMBRANES AND CLOTHING. READ THE WARNINGS AND FOLLOW DIRECTIONS ON THE CLEANER LABEL. CAUTION: NEVER LEAVE A CHLORINE SANITIZER IN CONTACT WITH STAINLESS STEEL FOR LONGER THAN 30 MINUTES.
  • Page 4 Table of Contents Important Operator Warnings ............page 2-3 References..................page 4 Equipment Description............... page 5-6 Inspection and Unpacking ............page 7 Installation .................. page 8-9 Initial Start-Up................page 9 Operation ................page 10-11 Sequence of Operation ..............page 12 Cleaning.................. page 13-14 Maintenance.................
  • Page 5 Equipment Description The BPM/BPP is a stainless steel, electrically heated Braising Pan which is equipped with integrated heating elements, a hand operated or motor powered tilting mechanism, electrical controls and a hinged cover. The Braising Pan serves as a braising unit, griddle, fry pan, oven, kettle, bain-marie, or food warmer and server. It can also be adapted for use as a non-pressure steamer.
  • Page 6 Equipment Description The following optional equipment may be added to any floor model listed above: Fill faucet - swing spout single or double pantry Fill faucet - 48” or 60” spray hose assembly - single or double pantry Caster mounting kit Flanged Feet Kit Draw-Off Valve (can not be field installed) Steamer insert set...
  • Page 7 Inspection & Unpacking CAUTION The unit will arrive completely assembled, wrapped in protective plastic on a heavy skid, SHIPPING STRAPS ARE UNDER TENSION in a heavy cardboard carton. Immediately upon receipt, inspect the carton for damage. AND CAN SNAP BACK WHEN CUT. Report any apparent shipping damage or an incorrect shipment to the delivery agent.
  • Page 8 Installation CAUTION Internal wiring for the Braising Pan is supplied complete. When you receive the unit, it BEFORE ANY ELECTRICAL CONVERSION, is ready for connection. A wiring diagram is located inside the control box on the right VERIFY THAT THE BRANCH CIRCUIT side of the pan, as well as in this manual.
  • Page 9 Installation For conversion from 3-phase to 1-phase Verify that the branch circuit wiring is adequate for any increased amperage requirements. (See table on previous page) 1-phase requires two jumper wires. One jumper wire exists on the terminal block for 3- phase input. The second jumper wire is located in a plastic bag inside the control box.
  • Page 10 Operation WARNING Controls KEEP THE AREA AROUND BRAISING PAN Operator controls for the braising pans are: FREE AND CLEAR OF COMBUSTIBLE MATERIALS. Power ON Switch and Power ON indicator located on the control console. CAUTION The thermostat dial, located on the control console to the right of the KEEP FLOORS IN BRAISING PAN WORK pan body.
  • Page 11 Operation CAUTION Cooking DO NOT HEAT AN EMPTY PAN FOR To simmer or slowly heat an item, set the dial at 210°F (99°C) or lower. Put MORE THAN FIVE MINUTES AT A the cover down to minimize moisture loss, or leave it up to help dry or reduce SETTING HIGHER THAN 300°F.
  • Page 12 Sequence of Operation The following “action-reaction” outline is provided to help you understand how the braising pan actually functions. When you start up the pan by turning the thermostat from “OFF” to a desired temperature, the thermostat switch closes. This causes the contactors to close, and allows power to flow to the heating elements and the indicator light.
  • Page 13 Cleaning Suggested Tools WARNING KEEP WATER AND SOLUTIONS OUT OF A good stainless steel cleaner Brushes in good condition CONTROLS AND ELECTRICAL EQUIPMENT. Cloth for cleaning controls DO NOT USE A HIGH PRESSURE HOSE TO Chlorine sanitizer CLEAN THE CONTROL CONSOLE, Heavy Duty Cleaner (if required) ELECTRICAL CONNECTIONS, ETC.
  • Page 14 Cleaning CAUTION 11. Following supplier instructions, apply the sanitizing agent after the unit has NEVER LEAVE A CHLORINE SANITIZER IN been cleaned and drained. Thoroughly drain off the sanitizer. CONTACT WITH STAINLESS STEEL SURFACES FOR LONGER THAN 30 MINUTES. 12. After the unit has been cleaned, sanitized and drained, let all surfaces air LONGER CONTACT CAN CAUSE CORROSION.
  • Page 15 Maintenance WARNING Your braising pan is designed to require minimum maintenance, but certain parts ELECTRIC POWER ALWAYS SHOULD BE may need replacement after prolonged use. After installation, no user adjustment SHUT OFF BEFORE WORK IS DONE ON should be necessary. If a service need arises, only authorized personnel should INTERNAL COMPONENTS.
  • Page 16 Troubleshooting Your braising pan will operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. If the actions suggested do not solve the problem, call your qualified Service Representative. If an item on the list is followed by X, the work should only be performed by a qualified service representative.
  • Page 17 Parts List Stand & Foot Assembly Description Part # CASTER KIT (SET OF 2 WITH 146354 BRAKE AND 2 W/O BRAKE) CASTER WITH BRAKE (W/O 146513 FOOT ADAPTER) CASTER WITHOUT BRAKE 146515 (W/O FOOT ADAPTER) NOT SHOWN FOOT ADAPTER 146516 FLANGED FOOT 146521 (W/O FOOT ADAPTER)
  • Page 18 Parts List Cover & Counterbalance Assemblies Key Qty Description Part # COVER & 162232 COUNTERBALANCE 162235 ASSEMBLY, 15 GALLON COVER & 144812 COUNTERBALANCE 145480 ASSEMBLY, 30 GALLON COVER & 144453 COUNTERBALANCE 144790 ASSEMBLY, 40 GALLON STUD WELD, 012589 1/4”-20 X 1-1/4” WASHER, LOCK 3/8”...
  • Page 19 Parts List OM-BPM/BPP-E 19...
  • Page 20 Parts List OM-BPM/BPP-E...
  • Page 21 Parts List To order parts, contact your Authorized Service Agent. Supply the model designation, serial number, part description, part number, quantity, and when applicable, voltage and phase. KEY DESCRIPTION PART NO. KEY DESCRIPTION PART NO. STAND ASSEMBLY - 15 GAL 155725 COVER ELEMENT HOUSING - 40 GAL 144343...
  • Page 22 Parts List Manual Tilt Assembly Key Qty Description Part # GEAR CARRIER 002624 SHAFT, HANDWHEEL 144834 GEAR, WORM 128001 GEAR SECTOR 009829 KEY GIB 012031 HANDWHEEL 139152 PIN ROLL 012614 SCREW SET SOCKET 012060 BEARING ROLLER 002790 BEARING SLEEVE 137239 PLUG PIPE 010286 FITTING GREASE 90...
  • Page 23 Parts List Power Tilt Assembly Key Qty Description Part # ELECTRIC TILT SHAFT 144791 POWER LIFT MOTOR 144794 [204/240 VOC] SHAFT COUPLING 144615 GEAR CARRIER ASSY 137880 CARRIER GEAR 002624 BEARING ROLLER 002790 BEARING SLEEVE 137239 PLUG PIPE 010286 FITTING GREASE 90 012195 GEAR, WORM 128001...
  • Page 24 Schematics 15 Gallon Manual Tilt TERMINAL BLOCK TERMINAL BLOCK [TB] [TB] 208/240/440/480 VAC 208/240 VAC 3 PHASE 1 PHASE SUPPLY SUPPLY 208/240V CONNECT APPROPRIATE TRANSFORMER LEAD TO MAIN VOLTAGE LINE 480V TRANSFORMER 440/480 V [XFMR] OPTION 24 VAC 24 VAC 24COM GRN/YEL GRN/YEL...
  • Page 25 Schematics 30 Gallon Manual Tilt TERMINAL BLOCK L3/X TERMINAL BLOCK [TB] [TB] 208/240/480 VAC 208/240 VAC 3 PHASE 1 PHASE L3/X SUPPLY SUPPLY 208/240V CONNECT APPROPRIATE TRANSFORMER LEAD TO MAIN VOLTAGE LINE 480V TRANSFORMER 480 V [XFMR] OPTION 24COM GRN/YEL GRN/YEL HEAT LAMP [OT]...
  • Page 26 Schematics 30 Gallon Power Tilt (208/240V) TERMINAL BLOCK TERMINAL BLOCK L3/X [TB] [TB] 208/240 208/240 3 PHASE 1 PHASE L3/X SUPPLY SUPPLY CONNECT APPROPRIATE TRANSFORMER LEAD TO MAIN VOLTAGE LINE FUSE RELAY [C1] PURPL RECTIFIER TRANSFORMER LIFT MOTOR [XFMR] 208/240 VOLT RELAY 24 VAC [C2]...
  • Page 27 Schematics 30 Gallon Power Tilt (480V) TERMINAL BLOCK TERMINAL BLOCK L3/X [TB] [TB] 480 VAC 480 VAC 3 PHASE 1 PHASE L3/X SUPPLY SUPPLY CONNECT APPROPRIATE TRANSFORMER LEAD TO MAIN VOLTAGE LINE RECTIFIER 480 V 115 V PURPLE RELAY RELAY [C2] [C1] TRANSFORMER...
  • Page 28 Schematics 40 Gallon Manual Tilt TERMINAL BLOCK TERMINAL BLOCK [TB] [TB] 208/240/480 VAC 208/240 VAC 3 PHASE 1 PHASE SUPPLY SUPPLY 208/240V CONNECT APPROPRIATE TRANSFORMER LEAD TO MAIN VOLTAGE LINE 480V TRANSFORMER 480 V [XFMR] OPTION 24 VAC 24 VAC 24COM GRN/YEL GRN/YEL...
  • Page 29 Schematics 40 Gallon Power Tilt (208/240V) TERMINAL BLOCK TERMINAL BLOCK L3/X [TB] [TB] 208/240 208/240 3 PHASE 1 PHASE L3/X SUPPLY SUPPLY CONNECT APPROPRIATE TRANSFORMER LEAD TO MAIN VOLTAGE LINE FUSE RELAY [C1] PURPL RECTIFIER TRANSFORMER LIFT MOTOR [XFMR] 208/240 VOLT RELAY [C2] 24COM...
  • Page 30 Schematics 40 Gallon Power Tilt (480V) TERMINAL BLOCK TERMINAL BLOCK L3/X [TB] [TB] 480 VAC 480 VAC 3 PHASE 1 PHASE L3/X SUPPLY SUPPLY CONNECT APPROPRIATE TRANSFORMER LEAD TO MAIN VOLTAGE LINE RECTIFIER 115 V 480 V PURPLE RELAY RELAY [C2] [C1] TRANSFORMER...
  • Page 31 Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-BPM/BPP-E 31...
  • Page 32 1055 Mendell Davis Drive • Jackson MS 39272 888-994-7636 • 601-372-3903 • Fax 888-864-7636 unifiedbrands.net PART NUMBER 148727, REV. E (04/13) © 2013 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.