Ex) Apply Holiday T/S
1. Set Holiday T/S
2. Save Holiday code when you when Time Schedule
3. Input Time Schedule index to [READER1 T/S]
READER2, READER3 and READER4 T/S set-up is the same as above.
1.6

READER OPEN CHECK SETTING

You should set to check whether Reader#1 (R1) is opened or not. Default is "NOT USE".
You can change the setting by pressing "4" or "6" key. After changing the setting, press
<ENT> key if the setting is completed.
NOT USE
In case of "NOT USE", it doesn't confirm to check about R1 (Reader#1) OPEN.
USE (ALONE)
When R1 (Reader#1) is open, the iTDC sounds beeper and makes event occur. In
result, you can confirm status on the PC.

READER OPEN STATUS:

The reader outputs "00000000" through reader's data wire once within 60sec. At this time, if
"00000000" is transmitted by the reader in the iTDC, the unit judges that reader is normally
connected. Therefore you can know connection status of reader without additional wiring.
R2 OPEN CHECK, R3 OPEN CHECK and R4 OPEN CHECK is the same as above.
p.78