Advertisement

Quick Links

版本号
A0
会签
谢良
夏巨江
刘红
帅维文
旧底图登记号
/
底图登记号
/
RFL-P120MX
120MX 激光器英文说明书
RFL-P120MX·JS02
部 门 脉冲激光器技术研究部
编 写
胡晓蕾 20210315
校 对
李 莎 20210316
审 核
李 科 20210322
标 审
李其军 20210322
批 准
黄 保 20210322
武汉锐科光纤激光技术股份有限公司
密级
内部
阶段
S
标记

Advertisement

Table of Contents
loading

Summary of Contents for Raycus RFL-P120MX

  • Page 1 版本号 密级 内部 阶段 标记 RFL-P120MX 会签 谢良 120MX 激光器英文说明书 夏巨江 RFL-P120MX·JS02 刘红 帅维文 部 门 脉冲激光器技术研究部 编 写 胡晓蕾 20210315 校 对 李 莎 20210316 审 核 李 科 20210322 标 审 李其军 20210322 批 准 黄 保 20210322 武汉锐科光纤激光技术股份有限公司...
  • Page 2 User Instruction RFL-P120MX Wuhan Raycus Fiber Laser Technologies CO., Ltd. 2021...
  • Page 3 Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying the power to the device, please make sure that the correct voltage of 24V DC is connected and the anode and cathode are right.
  • Page 4: Table Of Contents

    4.1. Pre-inspection ......................... 12 4.2. Operation procedures ......................12 4.3. Cautions ..........................12 5. Instructions for warranty, return and maintenance ..........13 5.1. General warranty ........................13 5.2. Limitations of warranty ......................13 5.3. Service and repairs ......................... 13 @2021 Raycus Corporation...
  • Page 5: Description

    Caution: Make sure the corresponding wires of the device are properly grounded. All the maintenance to the device should only be done by Raycus, because there is no replacement or accessory provided with the device. Please do not try to damage the labels or open the cover in order to prevent against electric shock, or the warranty will be invalid.
  • Page 6: Specifications

    Output beam diameter 350ns/80kHz/120W μs 0-100% power Laser switching ON time μs Laser switching OFF time 100-10% power Output fiber cable length Supply voltage Guide Laser Power Anti Strong Back Reflection Forced Air Cooled Cooling ℃ Operating Temperature @2021 Raycus Corporation...
  • Page 7 [kHz] PRRmin PRR0 [ns] 0.1-4W 1200 120-105W 2000 120-105W 0.2-4W 120-105W 2000 120-105W 0.3-4W 120-105W 1000 120-105W 0.5-4W 120-105W 1000 120-105W 0.8-4W 120-105W 1000 120-105W 1.25-4W 120-105W 120-105W 1.4-4W 120-105W 120-105W 1.5-4W 120-105W 120-105W 1.5-4W 120-105W 120-105W @2021 Raycus Corporation...
  • Page 8: Mounting

    Fix the module stable to the bracket and keep the laser in good ventilation. Connect the power line to 24V DC power and ensure enough DC output power. Keep it clear to the polarity of the electric current: Anode-brown, Cathode-blue, PE-yellow and green. @2021 Raycus Corporation...
  • Page 9 The recommended electrical connection is shown in Figure 4. Figure 5 Wiring diagram of recommended electrial connection and power supply The bending radius of the delivery fiber should not exceed 15 cm. @2021 Raycus Corporation...
  • Page 10: Control Interface

    0 to 100% (the actual laser power may not be strictly linear with the setting value). The relationship between Pin value and output power is shown in Table 5. Pin 10 and Pin 14are all digital GND. @2021 Raycus Corporation...
  • Page 11 ATTENTION: The frequency signal must be ahead of the EM signal at least 5 ms, otherwise the laser machine may be damaged. Below figure shows DB25 sequence diagram: Figure 7 DB25 sequence diagram @2021 Raycus Corporation...
  • Page 12 : If the laser output system is abnormal, the alarm might present “SYSTEM ERR” due to using different marking card (for example: Beijing JCZ Technology Co. marking card). Inside interface circuit of input and output signal from DB25: @2021 Raycus Corporation...
  • Page 13 Table 8 Command format of setting the laser pulse duration Frame( 1byte) Command word (1 byte)1 Pulse duration(2byte)ns 0xA5 0x01 Big Endian Table 9 Response format of setting the laser pulse duration Frame( 1byte) Pulse duration(2byte)ns 0xA5 Big Endian @2021 Raycus Corporation...
  • Page 14 Pin2 and Pin3 changing. Figure 14 shows the adjustment process of laser duration control. Pin19 should decrease to low state before adjusting laser pulse duration. Optional pulse width :10\20\30\60\100\200\250\350ns. Figure 10. Schematic of laser pulse duration adjustment(200ns) @2021 Raycus Corporation...
  • Page 15 2ns (minimum). If the setting duration is larger than the limiting maximum value, the duration of output laser will be continuous work (maximum). If the setting duration within the range, the duration of output laser will tend to the smaller side. @2021 Raycus Corporation...
  • Page 16: Operation Regulations

    Table 3). It should not modify the frequency while marking. Stop marking first before shutting down the device, then turn the power down to zero and cut the power off. @2021 Raycus Corporation...
  • Page 17: Instructions For Warranty, Return And Maintenance

    Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period. Only products with particular defects are under warranty.