Page 3
Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying the power to the device, please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right.
1) Caution: Make sure the corresponding wires of the device are properly grounded. 2) All the maintenance to the device should only be done by Raycus, because there is no replacement or accessory provided with the device. Please do not try to damage the labels or open the cover in order to prevent against electric shock, or the warranty will be invalid.
User’s guide Ytterbium Pulsed Fiber Laser RFL-P70Q~P100Q Ver.: 2.0 6) The device has four cooling fans at the rear panel to dissipate heat. In order to guarantee enough airflow to help giving heat off, there must be a space of at least 10 cm’s width for airflow in front and rear side of the device.
Page 8
User’s guide Ytterbium Pulsed Fiber Laser RFL-P70Q~P100Q Ver.: 2.0 definition figure is shown in Fig. 3. 24V- 24V+ Figure 3. Definition of power line wires 3) Make sure that the interface of the external controller matches the laser and the control cable is well connected to the laser’s interface.
User’s guide Ytterbium Pulsed Fiber Laser RFL-P70Q~P100Q Ver.: 2.0 3. Control Interface There are DB9 and DB25 interfaces at the rear of the laser. The DB9 is a RS232 interface only used for debugging, no needs to connect. And DB25 is the joint interface connecting control system with laser system, please make sure the connection is reliable before operation.
Page 10
User’s guide Ytterbium Pulsed Fiber Laser RFL-P70Q~P100Q Ver.: 2.0 laser output power from 0~100% (the actual laser power may not be strictly linear with the setting value). The relationship between PIN value and output power is shown in Table 4:...
Page 11
User’s guide Ytterbium Pulsed Fiber Laser RFL-P70Q~P100Q Ver.: 2.0 5) I/O connection of digital signal: the supply current of input signals are less than 10mA, and the supply current of output signals are less than 3 mA. The connection circuit of input and output signals is shown in Figure 6.
User’s guide Ytterbium Pulsed Fiber Laser RFL-P70Q~P100Q Ver.: 2.0 4. Operation Regulations 4.1 Pre-inspection 1) Make sure the device appearance is in good condition and the output fiber is neither excessively bended nor broken. 2) Make sure signal line of laser and marking system are properly connected.
Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period. Only products with particular defects are under warranty.