  • Page 1 RFL-P20MB 编号 密级 阶段标记 页数 名称 RFL-P20MB 脉冲光纤激光器英文使用说明书 会签 单位 第二事业部 编写 朱军 校对 李科 审核 施建宏 标审 李其军 批准 黄保 武汉锐科光纤激光技术股份有限公司...
  • Page 2 User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Ytterbium Pulsed Fiber Laser User’s Guide RFL-P20MB Wuhan Raycus Fiber Laser Technologies Co., Ltd.,2018 Proprietary information. All rights reserved Issued 19 October 2018...
  • Page 3  Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying the power to the device, please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right.
  • Page 4: Table Of Contents

    User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Content 1. Description....................1 1.1. Product description......................1 1.2. Actual configuration list....................1 1.3. Environmental requirements and cautions..............1 1.4. Specifications....................... .. 2 2. Mounting....................3 2.1 Mounting dimensions..................... 3 2.2 Method of installation....................4 3.
  • Page 5: Description

    1) Caution: Make sure the corresponding wires of the device are properly grounded. 2) All the maintenance to the device should only be done by Raycus, because there is no replacement or accessory provided with the device. Please do not try to damage the labels or open the cover in order to prevent against electric shock, or the warranty will be invalid.
  • Page 6: Specifications

    User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 6) The device has three cooling fans at the rear panel to dissipate heat. In order to guarantee enough airflow to help giving heat off, there must be a space of at least 10 cm’s width for airflow in front and rear side of the device.
  • Page 7: Mounting

    User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Supply voltage Power Consumption @25℃ Forced Air Cooled Cooling ℃ Operating Temperature ℃ Store Temperature Humidity 286× 215× 95 W× D× H Laser module dimensions 2. Mounting 2.1 Mounting dimensions 1) Fiber Laser module dimensions (As shown in Fig. 1).
  • Page 8: Method Of Installation

    User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Method of installation 1) Fix the module stable to the bracket and keep the laser in good ventilation. 2) Connect the power line to 24VDC power and ensure enough DC output power. Keep it clear to the polarity of the electric current: anode-brown;...
  • Page 9: Control Interface

    User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 3. Control Interface There are DB9 and DB25 interfaces at the rear of the laser. The DB9 is a RS232 interface only used for debugging, no needs to connect. And DB25 is the joint interface connecting control system to the laser system, please make sure the connection is reliable before operation.
  • Page 10: Pin 10 And Pin 14 Are All Digital Gnd

    User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 1) The pump current of diode laser and the laser output power are controlled by setting the value of PIN1-PIN8 (TTL level). PIN1-PIN8 can be set from 0~255,corresponding to the laser output power from 0~100%...
  • Page 11 User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Figure 6 DB25 sequence diagram T1:Represent the initialization time of the laser machine. The initialization time is less than 10s from power-on to perform initialization. T2:Represent the pump recharge time, usually around 5ms.
  • Page 12 User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 remain if the power or DB25 port is not well connected. PS 2: If the voltage or current states of the laser are abnormal, the alarm might present “POWER ERR” due to using different marking card (for example: Beijing JCZ Technology Co.
  • Page 13: Operation Regulations

    User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Figure 7 Schematic of laser pulse duration adjustment(200ns) For example, if using Beijing JCZ Technology Co. marking card to adjust laser pulse duration, the setting processes are described as follows: a) Make sure the power supply, DB25 cable, control card and computer are correctly connected, and then turn on the 24V power supply.
  • Page 14: Cautions

    Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period. Only products with particular defects are under warranty.
  • Page 15: Service And Repairs

    5.3 Service and repairs Raycus is responsible for all the maintenance, for there is no accessory available inside for users to use. Please contact Raycus as soon as possible when problems under warranty about maintenance happen to the product.