Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying the power to the device, please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right.
1) Caution: Make sure the corresponding wires of the device are properly grounded. 2) All the maintenance to the device should only be done by Raycus, because there is no replacement or accessory provided with the device. Please do not try to damage the labels or open the cover in order to prevent against electric shock, or the warranty will be invalid.
User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 6) The device has three cooling fans at the rear panel to dissipate heat. In order to guarantee enough airflow to help giving heat off, there must be a space of at least 10 cm’s width for airflow in front and rear side of the device.
User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Method of installation 1) Fix the module stable to the bracket and keep the laser in good ventilation. 2) Connect the power line to 24VDC power and ensure enough DC output power. Keep it clear to the polarity of the electric current: anode-brown;...
User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 3. Control Interface There are DB9 and DB25 interfaces at the rear of the laser. The DB9 is a RS232 interface only used for debugging, no needs to connect. And DB25 is the joint interface connecting control system to the laser system, please make sure the connection is reliable before operation.
User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 1) The pump current of diode laser and the laser output power are controlled by setting the value of PIN1-PIN8 (TTL level). PIN1-PIN8 can be set from 0~255,corresponding to the laser output power from 0~100%...
Page 11
User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Figure 6 DB25 sequence diagram T1:Represent the initialization time of the laser machine. The initialization time is less than 10s from power-on to perform initialization. T2:Represent the pump recharge time, usually around 5ms.
Page 12
User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 remain if the power or DB25 port is not well connected. PS 2: If the voltage or current states of the laser are abnormal, the alarm might present “POWER ERR” due to using different marking card (for example: Beijing JCZ Technology Co.
User’s guide Ytterbium Pulsed Fiber Laser RFL-P20MB Ver.: 2.0 Figure 7 Schematic of laser pulse duration adjustment(200ns) For example, if using Beijing JCZ Technology Co. marking card to adjust laser pulse duration, the setting processes are described as follows: a) Make sure the power supply, DB25 cable, control card and computer are correctly connected, and then turn on the 24V power supply.
Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period. Only products with particular defects are under warranty.
5.3 Service and repairs Raycus is responsible for all the maintenance, for there is no accessory available inside for users to use. Please contact Raycus as soon as possible when problems under warranty about maintenance happen to the product.