Page 3
Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying the power to the device, please make sure that the correct voltage of 24V DC is connected and the anode and cathode are right.Incorrect polarityor voltage will harm...
The figure of Raycus P20MX pulse fiber laser is shown in Figure 2. The laser is pumPing by the way of fiber coupling output semiconductor laser, so the efficiency of pump light conversion is very high.The laser uses air cooling system and thefan can change speed in real time according to the...
Caution: Make sure the corresponding wires of the device are properly grounded. All the maintenance to the device should only be done by Raycus, because there is no replacement or accessory provided with the device. Please do not try to damage the labels or open the cover in order to prevent against electric shock, or the warranty will be invalid.
Page 7
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 For any higher pulse duration τ higher than τ =500 ns the emission is CW. Figure 4. shows the pulse waveforms at full-power outpower for different pulse duration τ at the corresponding cut-off pulse repetition rates PRR Table 2.
Page 8
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 Figure 3. The pulse waveforms corresponding to the maximum single pulse energy Figure 4. Relation between pulse repetition rate PRR and maximum average power P Table 3. Pulse repetition rate PRR according to Figure 3. and maximum pulse energy E Pules different pulse duration τ.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 Figure 7. Wiring diagram of recommended electrial connection and power supply Method of installation Fix the module stable to the bracket and keep the laser in good ventilation.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 3. Control Interface There are DB9 and DB25 interfaces at the rear of the laser. The DB9 is a RS232 interface only used for debugging, no needs to connect. And DB25 is the joint interface connecting control system to the laser system,please make sure the connection is reliable before operation.
Page 13
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 represent the frequency switching time. Frequency needs to be adjusted before optical laser output, and the switching time should not less than 5ms. 2-8mswith external frequent mode, recommend 4ms.
Page 14
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 Table 7. Laser duration control signal Name Description The setting of the data bits synchronize with rising edge of Serial input theserial clock. Serial clock Serial clock, frequency range: 10kHz~1MHz.
Page 15
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 For example, if using Beijing JCZ Technology Co. marking card to adjust laser pulse duration, the setting processes are described as follows: Make sure the power supply, DB25 cable, control card and computer are correctly connected, and then turn on the 24V power supply.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P20MX Pulsed Fiber Laser User’s Guide V1 4. Operation Regulations Pre-inspection Make sure the device appearance is in good condition and the output fiber is neither excessively bended nor broken. Make sure signal line of laser and marking system are properly connected.
Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period. Only products with particular defects are under warranty.