TEST RESULTS - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
I2450
Run #:
2
Average Gas Velocity in Dilution Tunnel (ft/sec)
Average Gas Flow Rate in Dilution Tunnel (dscf/hr)
Particulate Concentration, dry-standard (g/dscf)
Difference from Average Total Particulate Emissions (g)
Difference from Average Emissions Factor (g/kg)
Quality Checks
Dual Train Precision
Filter Temps
Face Velocity
Leakage Rate
Ambient Temp
Negative Probe Weight Evaluation
Pro-Rate Variation
PFS-TECO
Burn Rate (kg/hr):
Total Sample Volume (ft
Average Gas Meter Temperature (°F)
Total Sample Volume (dscf)
Average Tunnel Temperature (°F)
Total Time of Test (min)
Total Particulate Catch (mg)
Total PM Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
Final Average Results
Total Particulate Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
HHV Efficiency (%)
LHV Efficiency (%)
CO Emissions (g/min)
Requirement
Each train within 7.5% of average emissions (in
grams), or emission factors within 0.5 g/kg
>80 °F, <90 °F
< 30 ft/min
Less than 4% of average sample rate
55-90 °F
<5% of Total Catch
90% of readings between 90-110%; none greater
than 120% or less than 80%
Page 2 of 53
Job #:
Tracking #:
Technician:
Date:
1.10
Ambient
Sample
Sample
Train A
3
)
61.013
80.013
80.5
90.3
59.936
78.023
0.1
5.9
0.0000017
0.0000756
0.16
7.22
0.02
0.82
-
0.75
-
0.39
-
0.04
6.83
0.78
0.71
68.2%
73.0%
1.43
Observed
See Above
Min: 84 / Max: 88
9.4
0.002 cfm
Min: 78 / Max: 84
Probe Catch Not
Negative
See Data Tabs
19-469
0025
ADK/SJB
4/9/2019
Sample
1st Hour
Train B
Filter
78.193
9.019
17.06
11152.5
105.0
87.4
73.951
8.840
103.0
525
5.0
3.0
0.0000676
0.0003393
6.44
3.77
0.74
3.77
0.67
-
-
0.39
-
0.04
Result
OK
OK
OK
OK
OK
OK
CHECK 10 MIN. INTERVAL
PRO-RATES

Advertisement

Table of Contents
loading