FPI I2450M Manual page 107

Wood-fired fireplace insert
Table of Contents

Advertisement

Client: FPI
Model: I2450
Pre-Test Notes
Pre-Test Start Time:
Air Control Setting:
Time
0:00
Started PB with 1.8 lb, torch for 25 sec
2:30
Closed door (1.2 lb)
8:00
Loaded 2.3 lb of kindling & startup (@ 0.5 lb)
20:00
Loaded remaining 2.5 lb of startup (@ 0.7 lb)
26:00
Leveled coal bed (2.1 lb)
27:00
Loaded high burn fuel
105:00
Leveled coal bed (6.0 lb)
Test Notes
Test Burn Start Time:
Air Control Setting:
Time
1:00
Fuel loaded, door closed
13:00
Air set
17:00
Changed filter A
18:00
Changed filter B
30:00
Fan on
60:00
Changed filter A
Test Burn End Time:
Calibration Gas Values:
Calibration Results:
Zero
Time
08:35
CO
0.01
2
CO
0.000
Flue Gas Probe Leak Check:
Technician Signature:
ASTM E3053 Wood Heater Run Sheets
Job Number: 19-469
Run Number: 2
Wood Heater Run Notes
08:20
Fully Open
10:25
Fully Closed
19:10
Flue Gas Concentration Measurement
Span Gas
Mid Gas
Pre Test
Mid
09:02
10.01
2.493
Initial: No Leakage
Notes
Notes
CO
(%): 16.93
CO (%): 4.33
2
CO
(%): 10.00
CO (%): 2.51
2
Span
Zero
09:00
4/10 09:35
16.93
0.00
4.330
0.000
Final: No Leakage
Date:
Tracking #: 0025
Test Date: 4/9/2019
Post Test
Mid
Span
4/10 09:38
4/10 09:40
10.03
16.95
2.504
4.345
4/19/2019
Page 1 of 3