FPI E33-NG1 Owners & Installation Manual

E33 gas insert

Advertisement

Quick Links

WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury, property damage, or loss
of life. Refer to this manual. For assistance or additional
information consult an authorized installer, service agency
or the gas supplier.
FOR YOUR SAFETY:
Do not store or use gasoline or other fl ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
Tested by:
918-513b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4
E33 Gas Insert
MODELS:
Owners & Installation Manual
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
E33-NG1 Natural Gas
FOR YOUR SAFETY:
What to do if you smell gas:
 Do not try to light any appliance
 Do not touch any electrical switch:
do not use any phone in your
building.
 Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
 If you
supplier, call the fi re department.
E33-LP1 Propane
cannot reach your gas
12/15/08

Advertisement

Table of Contents
loading

Summary of Contents for FPI E33-NG1

  • Page 1 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-513b FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4 12/15/08...
  • Page 2 The E33 Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The E33-NG1 and E33-LP1 have been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    Standard Flush Door ...........21 Flush Louvers ..............21 Full Screen Doors ............21 ® Excalibur Surround ...........22 Excalibur Screen Doors ..........23 Excalibur Accent Kit ............23 Wiring Diagrams ............24 Optional Remote Control ..........25 Optional Wall Thermostat ...........25 E33 FPI Direct Vent Gas Insert...
  • Page 4: Safety Label

    * Alcove side wall must have a min. of 8” clearance on one side. The State of Massachusetts requires the FPI Fireplace Products International Ltd., Delta BC, CANADA installation of a carbon monoxide alarm in MADE IN CANADA / FABRIQUE AU CANADA...
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. E33 FPI Direct Vent Gas Insert...
  • Page 6: Installation

    Canadian Safety Standards FACTORY BUILT The FPI Gas Insert must be installed in accord- and ANSI Standards to make you aware of FIREPLACE ance with these instructions. Carefully read all the following: the instructions in this manual fi...
  • Page 7: Installation Checklist

    Faceplate & Trim the hazards of high surface temperatures, d. Standard Flush Door The minimum fi replace opening for the FPI especially the fi replace glass, and should e. Flush Louvers gas fi replace insert is shown in the following stay away to avoid burns or clothing f.
  • Page 8: Combustible Mantel Clearances

    Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. E33 FPI Direct Vent Gas Insert...
  • Page 9: Venting

    3" Flex - 35 ft. 4) Connect the 2nd liner to the inlet side of 946-529 FPI Co-linear DV Vertical the adaptor, seal connection with high Termination Cap temperature silicone. Secure with gear clamp. E33 FPI Direct Vent Gas Insert...
  • Page 10: Gas Insert Aeration System

    Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Note: Aeration Adjustment should only be performed by an authorized FPI Installer at the time of installation or service. E33 FPI Direct Vent Gas Insert...
  • Page 11 (refer to Diagram 4). Diagram 1 Completed Installation 5) Place the top bracket onto the top edge of the top panel (refer to Diagram 2). Top Bracket Diagram 4 Diagram 2 E33 FPI Direct Vent Gas Insert...
  • Page 12: Log Set Installation

    (refer to Diagram 3) box. Please handle with care and do not force them into position to avoid chipping. 03-23 2) Remove the top louver and glass door if already installed. Locating Pins Diagram 3 E33 FPI Direct Vent Gas Insert...
  • Page 13 03-20 (refer to Diagram 9 & 10). touches the locating tab. (see Diagram 6 & 7) 03-23 03-18 03-20 Locating Pins Locating Locating 03-20 03-21 Diagram 6 Diagram 9 E33 FPI Direct Vent Gas Insert...
  • Page 14 03-23 and the right pin of log 03-21 13) Separate platinum embers and place at the front (refer to Diagram 11). of the burner. Avoid stacking platinum embers. 03-24 03-23 Locating Pins 03-21 Diagram 11 E33 FPI Direct Vent Gas Insert...
  • Page 15: Conversion Kit# 731-969 From Ng To Lp

    Installation section in E33 Manual). Ensure you slide the bottom log 03-17 off to the right-hand side to avoid chipping. Burner Orifi ce Removal Fig.3 9) Reinstall new burner orifi ce LPG stamped #50 and tighten. E33 FPI Direct Vent Gas Insert...
  • Page 16 0 - 4500 ft. (0 - 1370m). 30) Connect the DC spark generator wires to the SIT Valve with the screw, which is 17) Re-assemble the black protection cap provided in the kit. (Fig. 6). Fig. 6 E33 FPI Direct Vent Gas Insert...
  • Page 17 DC spark generator wires through the bushing on the heat shield. 38) Mount the heat shield to the DC Sparker. Heat Shield Secure into place with the velcro, which is provided in the kit. E33 FPI Direct Vent Gas Insert...
  • Page 18: Faceplate & Trim

    4 remaining black screws. faceplate panel. Refer to Diagram 5. Rear View: Faceplate Assembly Diagram 1 Diagram 5 11) Push the FPI logo plate into the two holes in the bottom left corner of the faceplate. E33 FPI Direct Vent Gas Insert...
  • Page 19: Contemporary Faceplate & Door Frame

    2) Connect the grey coated female ends of the black & red fan wires from the unit to the male ends of the fan rheostat on the left side of the faceplate as shown. Faceplate Tabs Fan Rheostat E33 FPI Direct Vent Gas Insert...
  • Page 20 7) Secure the hinge to the bottom fl ange of the fi rebox with 2 screws Glass Door Door Frame Flange from step 6. Repeat for other side. 10) Close the bottom louver. Completed Faceplate & Door Frame Installation Spacer Screw E33 FPI Direct Vent Gas Insert...
  • Page 21: Standard Flush Door

    Connect the fan switch wires with the wire connectors from the fan speed control. Place To remove the fl ush door, reverse the above Screw clips over wires and tuck into side trim. steps. Top Frame E33 FPI Direct Vent Gas Insert...
  • Page 22: Excalibur ® Surround

    NOTE: If you are installing the Excalibur ® Glass the minimum fi replace dimensions are Door as follows: Width (at front): 34-1/2" (876mm) Depth: 17-3/4" (451mm) Hinge Height: 26" (660mm) Diagram 2 Screen Door E33 FPI Direct Vent Gas Insert...
  • Page 23: Excalibur Screen Doors

    Put the studs through the holes and secure Surround round. them by tightening them with a nut. E33 FPI Direct Vent Gas Insert...
  • Page 24: Wiring Diagrams

    NATURAL GAS Units and Units Equipped with DC Spark Boxes CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. E33 FPI Direct Vent Gas Insert...
  • Page 25: Optional Remote Control

    *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. OPTIONAL REMOTE CONTROL OPTIONAL WALL THERMOSTAT Use the FPI Remote Control Kit approved for CAUTION this unit. Use of other systems may void your Do not connect the millivolt A wall thermostat may be installed if desired, warranty.
  • Page 26: Operating Instructions

    Note: When the glass is cold and the operated with the glass door removed. appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up. E33 FPI Direct Vent Gas Insert...
  • Page 27: Copy Of Lighting Instruction Plate

    Blower: FPI gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON.
  • Page 28: Maintenance

    (not with wall paint). and any gas control which has been under in the inner liner, and subsequently dripping FPI uses StoveBrite Paint - Metallic Black water. out the joints. Continuous condensation can #6309.
  • Page 29: Door Glass

    To Remove Fan: the 2 screws. 1) Turn the unit off and allow it to cool down to Your FPI stove is supplied with high temperature, room temperature. 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. Do...
  • Page 30: Valve Assembly Removal And Installation

    NG and 11" W.C. for LP. 3) Shut off the main gas supply. 21) Reverse steps 4-8. 4) Remove the louvers and glass door. 5) Remove logs and grate. 6) Remove optional brick set, if installed. E33 FPI Direct Vent Gas Insert...
  • Page 31: Parts List

    Adaptor Holding Brkt - Right 48) 340-523 Flue Adaptor Assembly 49) 340-099 Thermal Insulation 50) * Insulation Hold Down Bracket 51) * Louver Hold Down - Top 918-513 Manual * Not available as a replacement part. E33 FPI Direct Vent Gas Insert...
  • Page 32: Burner & Log Assembly

    82) 340-047 Burner Grate 340-930 Complete Log Set Bottom Log Center Top Log Front Log Left Log Right Log Top Left Log Rear Log Top Right Log * Not available as a replacement part. E33 FPI Direct Vent Gas Insert...
  • Page 33: Full Screen Front

    Full Screen Door - Black 85) * Full Screen Left Door 86) * Full Screen Right Door 87) * Bottom Frame 88) * Screw #8 x 1/2 Self Tapping 89) 910-199 Wire Clip Holder 90) 948-042 Hinge Spring E33 FPI Direct Vent Gas Insert...
  • Page 34: Faceplates, Trims And Hearths

    97) 910-246 Burner ON/OFF Switch 98) 910-330 Fan Speed Control 120 V 99) * Faceplate Filler 95/96 LO GO LO GO PL AT PL AT EH ER EH ER REAR VIEW (ASSEMBLED) FRONT VIEW E33 FPI Direct Vent Gas Insert...
  • Page 35: Contemporary Faceplate & Door Frame

    Complete Faceplate 91) * Door Frame 92) * Bottom Louver 93) * Hinges 910-246 Burner ON/OFF Switch 910-330 Fan Speed Control 120V 904-569 Fan Speed Control Knob * Not available as a replacement part. E33 FPI Direct Vent Gas Insert...
  • Page 36 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ E33 FPI Direct Vent Gas Insert...
  • Page 37 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ E33 FPI Direct Vent Gas Insert...
  • Page 38 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ E33 FPI Direct Vent Gas Insert...
  • Page 39: Warranty

    Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
  • Page 40 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency and Excalibur are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved.