Check Direction Of Rotation Of Motor [Lsv 560/8] (29); Reversing Phases Of The Mains Volt- Age [Lsv 560/8] (30); Carry Out Function Check (31); Operation - AL-KO LSV 550/6 Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 28
GB
3. Lay the mains cable in such a way that it can-
not be kinked, crushed or damaged in any
other way.
4. Open vent screw (01/15, 02/15) by roughly 1
– 2 turns so that the air can escape that is
displaced during operation by the heated and
expanding oil.
5. Plug the mains cable into plug socket (01/14,
02/14) of the appliance and then connect the
mains cable to the mains power supply.
Note: During disconnection, first disconnect
the mains cable from the mains power sup-
ply.
6.2
Check direction of rotation of motor
[LSV 560/8] (29)
IMPORTANT! Danger of damage to the hy-
draulic pump. The hydraulic pump will be dam-
aged if the motor rotates in the wrong direction.
Switch off the log splitter again immediately if
the motor rotates in the wrong direction or the
splitting wedge does not move upwards after
switching on.
Reverse the phases of the mains voltage.
1. At the same time:
Press green button (29/1) and then red
button (29/2) to allow the motor to run
briefly.
Observe the direction of rotation of the
motor through ventilation slots (29/3).
The direction of rotation must correspond
to the arrow (29/4) on the motor and the
splitting wedge must move upwards.
Note: If the splitting wedge is already in
the highest position, press the operating
arms briefly together and briefly down-
wards.
2. If the direction of rotation is not correct or the
splitting wedge does not move:
Stop the motor immediately.
Reverse the phases of the mains voltage:
see chapter 6.3 "Reversing phases of the
mains voltage [LSV 560/8] (30)",
page 36.
6.3
Reversing phases of the mains voltage
[LSV 560/8] (30)
1. Switch off the log splitter immediately and un-
plug the mains cable.
2. Insert a flat-tip screwdriver into phase invert-
er (30/1) in mains plug socket (30/2) of the
log splitter.
36
3. Press in the phase inverter and turn by 180°.
4. Plug in the mains cable.
5. Switch on the log splitter and check the direc-
tion of rotation of the motor again, see chap-
ter 6.2 "Check direction of rotation of motor
[LSV 560/8] (29)", page 36.
6.4

Carry out function check (31)

1. Press green button (31/1) to switch on. The
splitting wedge (31/2) automatically moves
upwards.
If the splitting wedge is already in the up-
permost position, briefly press the two
operating arms (31/3) together and
downwards, then switch the log splitter
off and on again. Press red button (31/4)
to switch off.
On LSV 560/8, if the splitting wedge does
not move upwards: Switch off the log
splitter immediately to prevent appliance
damage. Check direction of rotation of
the motor and correct, if necessary (see
chapter 6.2 "Check direction of rotation of
motor [LSV 560/8] (29)", page 36).
2. Carry out function check:
Press both operating arms together and
downwards simultaneously. The splitting
wedge must move downwards and stop
approx. 5 cm above the uppermost table
position.
Release one of the operating arms. The
splitting wedge must stop in the momen-
tary position.
Release both operating arms simultane-
ously. The splitting wedge moves up-
wards.

7 OPERATION

WARNING! Risk of injury if operated by
more than one person. Operation of the appli-
ance by two or more persons can result in seri-
ous injuries.
Operate the appliance only alone and never
reach into the splitting area during splitting.
Keep other persons away and in particular
prevent them from reaching into the log that
is currently being split.
Operation
LSV 550/6 | LSV 560/8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lsv 560/8

Table of Contents