When [LAN] is selected for control, [Power supply] and [Quick Start] are set to [Off]
Home mode
• When no signal is input, "No signal" is displayed and the monitor enters the auto power save mode after a while.
• During auto power save mode, the monitor enters the auto standby mode if no LAN signal is received for 3 minutes.
If a LAN signal is input during auto standby mode, the auto power save mode is not resumed. To maintain the auto power
save mode, use the Office mode.
• When a signal is input into the selected input terminal, the On mode is resumed.
When the AV terminal and VGA (YPbPr) terminal are selected, the On mode is not resumed even if a signal is input. In this
case, enable the Quick Start function. (With this function enabled, the On mode is resumed.)
Retail mode
• The monitor does not enter the energy-saving mode when no signal is input. (The On mode is maintained.)
Office mode
• When no signal is input, "No signal" is displayed and the monitor enters the auto power save mode after a while.
The auto power save mode is maintained regardless of LAN signal input.
• When a signal is input into the selected input terminal, the On mode is resumed.
When the AV terminal and VGA (YPbPr) terminal are selected, the On mode is not resumed even if a signal is input. In this
case, enable the Quick Start function. (With this function enabled, the On mode is resumed.)
CAUTIONE:
During auto power save mode and standby mode, if the power cord is disconnected and then plugged

again, the On mode will not be resumed automatically when a signal is detected.