Battery Charger
5
Troubleshooting
NUMBER OF
FLASHES
Charge canceled because of
inadequate input voltage to
3
Voltage output decreased
because of high internal
charger temperature.
Battery could not be trickle
charged up to minimum
4
Charger shutdown because of
high internal charger
5
Charger internal fault
6
Page 40
FAULT
charger.
voltage
temperature.
RECOMMENDED SOLUTION
Inspect for loose or corrosion connections. Tighten
loose connections and replace corrosion
connections.
Inspect for worn or defective batteries. Replace
batteries as necessary.
Operate charger in a lower ambient temperature
environment.
Inspect for worn or defective batteries. Replace
batteries as necessary.
Inspect for dirty, blocked, or damaged cooling fins.
Clean dirty cooling fins and remove blockages as
necessary. Replace damaged fins immediately.
Reset charger by removing electrical power for a
minimum 15 seconds.
Reset charger by removing electrical power for a
minimum 15 seconds.
Return charger to an approved service center if fault
persists.