Solid-State Relay Replacement; Figure 6 Thermocouple Replacement; Figure 7 Solid Relay Replacement - Thermo Scientific BF51728 Installation And Operational Manual

Lindberg/blue m moldatherm 1100 c box furnace
Table of Contents

Advertisement

1100°C Box Furnace
9. Replace the gas inlet tube assembly.

Figure 6 Thermocouple Replacement

Solid-State Relay Replacement

If the SSR is inoperable, complete the following steps to replace the relay (refer to
Figure 7 "Solid Relay Replacement"):
1. Remove the screws located on the left and right sides of the control panel (item #1 in
Figure 7).
2. Slide the panel assembly away from the unit to expose components.
3. Locate the SSR on the component tray (item #2 in Figure 7).
4. Note the terminal connections of the relay wires and label them for reattachment.
Remove the wires from the terminals of the relay.
5. Remove the mounting screws from the relay.
6. Replace the relay and reconnect the wires.
Maintenance |
Chapter 9
330985H01 | 9-57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bf51748Bf51766Bf51794Bf51828Bf51848Bf51866 ... Show all

Table of Contents