Troubleshooting; Product Specifications - Tanita ViScan AB-140 Instruction Manual

Abdominal fat analyser
Table of Contents

Advertisement

Troubleshooting

Please try the following prior to arranging repairs.
Problem
Impedance meter error.
Buzzer does not sound,
or
or
displayed.
Impedance meter Power
LED does not come on.
Communication error.
is displayed after the
buzzer sounds.
Measu
ring
The waist circumference
displayed is too large or
too small.
or
is displayed
after waist measurement
is completed.
or
is displayed
after calibration.
is displayed.
Nothing is displayed when
Display
the power is turned on.
The Charging LED does
not light up even when
charging has commenced.
34
Try This
•Store the impedance meter in the main unit to reset the
impedance meter status.
•Ensure the abdomen is sufficiently wet (shave
abdominal hair if thick).
is
•Check remaining impedance meter battery level (ensure
Power LED is on).
•Move the impedance meter switch hanger.
•Replace batteries.
•Place the impedance meter directly underneath the main
unit..
•Do not move the equipment during data communication.
•Ensure that the infrared ray transmitter and receiver are
clean. To clean, wipe with a soft cloth.
•Ensure that nothing is covering the infrared transmitter
and receiver during transmission.
•Ensure that no clothes or other obstacles are within a
10cm area centred on the navel when measuring.
•Ensure that the abdomen is not in contact with the
distance sensors during waist measuring.
•Ensure that the distance sensors are clear of dirt or
moisture. Remove any dirt or moisture with a soft, dry cloth.
•Calibrate.
•Check the waist size of the subject.
•Calibrate.
•Ensure the subject does not move while measuring the
waist.
•Ensure no obstacles are between the distance sensors
when calibrating.
•Re-calibrate.
•There is insufficient charge left in the main unit battery.
Recharge immediately.
•Check the AC adapter connection.

Product Specifications

Model
Measuring method
Measuring frequency
Measuring current
Impedance Meter
Electrode material
Measuring site
Measuring range
Power source
Measuring method
Measuring range
Battery
Main Unit
Power source
Light emitter
Laser wavelength
Laser output
Laser
(for positioning)
Beam size
Classification
Estimated waist circumference
Trunk % fat
Display
Visceral fat level
Trunk % fat determination
Visceral fat level determination
Settings
Total Weight
External interface
Usage temp. range
Temperature range for storage
AB-140
4 electrode format
6.25kHz, 50kHz
500 µA
Stainless steel
Abdomen (at navel)
5 – 100 Ω
DC 6V/4 LR03 alkaline batteries (included)
Near infrared reflectance
20 – 48cm
(correlates to estimated waist circumference of 50 – 130cm)
Nickel-hydrogen rechargeable batteries; output DC 7.2V, 1mAh
AC adapter
Input: 100 – 240V
Output: 12V, 2A
Plug: centre minus
Visible light semiconductor laser
Wavelength: 650 nm (red light)
Max. 1mW
At a distance of 200mm: minimum line length
200mm; light width max. 2mm
Point ± 5mm from the centre (point is approx. Ø 1.5).
Class 2M
50 -130cm (increment: 1cm)
For
Increment: 0.1% (5.0 – 75%)
subjects
1.0 – 59.0 levels (increment: 0.5 level)
18 years
Low – high (with bar indicator)
and over
6 levels from average – excessive (with bar indicator)
Male / Female
Main unit: approx 2.6kg; Impedance meter: approx. 0.5kg
RS232C output (D sub 9 pin connector, female)
-5 – +35ºC
-10 – + 50ºC
35

Advertisement

Table of Contents
loading