9.17 Adjusting Maximum Heating Power
Maximum boiler heating power can be reduced to suit
requirements of heating system it serves.
Table showing parameter P13 values according to desired
maximum power model is shown for each single boiler.
To access and edit P13 values, proceed as described in
Section 9.15 Parameter Settings.
Boiler Model - PARAMETER P13 (%)/ Heating Output
Btu/h
KW
20,400
6.0
23,800
7.0
27,200
8.0
30,700
9.0
34,100
10.0
40,900
12.0
47,700
14.0
54,500
16.0
61,400
18.0
68,200
20.0
75,100
22.0
81,900
24.0
88,700
26.0
95,500
28.0
102,300
30.0
109,200
32.0
112,600
33.0
9 - START UP PROCEDURE
DCBF-125 DCCF-150
0
0
4
3
7
6
11
9
15
12
22
18
30
24
37
29
44
35
52
41
59
47
67
53
74
59
80
65
88
71
96
75
100
80
Btu/h
27,400
31,300
35,800
41,300
46,500
55,900
65,700
74,500
83,200
92,300
101,900
110,000
118,000
127,000
136,900
145,300
151,700
47
kW
8.0
0
0
9.2
4
3
10.5
7
6
12.1
11
9
13.6
15
12
16.4
22
18
19.3
30
24
21.8
37
29
24.4
44
35
27.0
52
41
29.9
59
47
32.2
67
53
34.8
74
59
37.2
80
65
40.1
88
71
42.6
96
75
44.4
100
80