HP ProCurve 2824 Install Manual page 39

Procurve 2800 series
Hide thumbs Also See for ProCurve 2824:
Table of Contents

Advertisement

The following picture demonstrates and example of connectivity between an
EPS/RPS device and a Switch device.
RPS Power: 12V
Device Connected
R1
R2
RPS 1
RPS 2
RPS 3
Power Status
RPS output port
EPS/RPS Operation
The EPS/RPS monitors the power signal from the switch by detecting that the
EPS/RPS is connected to a switch with an EPS/RPS cable. When the power
from the switch is no longer detected, the EPS/RPS will turn on and provide
power to the switch within 1ms.
The EPS/RPS supports hot plugging of the EPS/RPS cable without causing a
reboot of the switch or causing the power supply in either the EPS/RPS or
switch to shut down temporarily or permanently. For more information refer
to the documentation that came with the EPS/RPS.
Console
Switch 2848, RPS input port
backup to one connected device. Lowest-numbered port has priority.
R3
R4
RPS 4
RPS 5
Installation Procedures
HP ProCurve RPS Input
EPS Power: 50V
370W total for PoE applications. Power is shared when
R5
R6
E1
RPS 6
EPS 1
EPS 2
Installing the Switch
Line: 50/60 Hz.
100-127 V~ 0.6A (0,6A)
200-240 V~ 0.3A (0,3A)
both ports are used.
Device
E2
Connected
Power
Status
Line: 50/60 Hz.
10 0 - 2 4 0 V~ 9.1A (9,1A)
2-21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 2848J4904aJ4903a

Table of Contents